Signal Generator:
Searching for the Direct Connected Signal
The Search pattern used to find the Signal Generator signal when
applied by a direct connection method (Direct Connection Leads,
Signal Clamp or Signal Injector) is different to the normal search
pattern used on Power or Radio Modes.
1. Move a few paces away from where the Signal Generator has been
connected to the service. Turn the mode switch to Generator mode.
Hold the locator so that the side of the locator is facing towards the
Signal Generator.
2. Adjust the Sensitivity so that the locator is just showing a visual
response and emitting an audible response.
3. If possible walk in a COMPLETE circle around the connection point
trying to keep the same distance from this point at all times. When a
signal is detected, ‘pinpoint’ that signal as shown in the ‘Using the
Locator’ section.
4. Having pinpointed the first signal, do NOT readjust the Sensitivity
control but continue with the circle to see if any other signals are
detected. If more signals are detected compare the strength of each
signal by observing the bar display. The strongest signal will usually
be coming from the service that the Signal Generator is connected to.