background image

Droplet

 

size

 

is

 

controlled

 

by

 

the

 

spraying

 

pressure. 

 
 

OPERATION

 

 

With

 

water

 

in

 

the

 

spray

 

tank; 

Fold

 

the

 

boom

 

out. 

Turn

 

on

 

the

 

pump,  

-12V

 

sprayers;

Switch

 

labeled

 

‘PUMP’

 

on

 

the

 

switch

 

box 

Ensure

 

hoses

 

and

 

lines

 

are

 

free

 

of

 

kinks

 

and

 

blockages. 

Allow

 

time

 

for

 

the

 

air

 

to

 

be

 

expelled

 

from

 

the

 

hoses

 

and

 

lines.  

Water

 

should

 

flow

 

evenly

 

out

 

of

 

the

 

spray

 

tips. 

Droplets

 

will

 

be

 

formed

 

by

 

the

 

nozzles,

 

thus

 

creating

 

the

 

spray. 

Drive

 

forward

 

at

 

the

 

required

 

operating

 

speed

 

across

 

target

 

area. 

 
 

CALIBRATING

 

YOUR

 

PRESSURE

 

NOZZLE

 

BOOM  

 

Metric

 

Version

 

(litres,

 

metres,

 

kph) 

(*Standard

 

nozzle

 

spacing

 

0.5

 

metres) 

 

You will need to calibrate your sprayer to ensure the accurate application of chemical or liquid fertilizer. If too much

 

 

   

 

 

   

 

 

 

   

   

 

   

 

 

chemical or liquid fertilizer is applied you will be wasting money! If too little is applied you may need to repeat the

   

 

   

 

 

   

 

   

 

   

 

 

 

   

 

 

spraying,

 

which

 

will

 

be

 

wasting

 

your

 

money

 

and

 

time! 

 
Chemicals

 

are

 

expensive.

 

​​

 

Repeat

 

calibration

 

frequently

 

during

 

the

 

seasons

 

to

 

avoid

 

disappointment.   

 
To

 

calibrate

 

your

 

sprayer

 

you

 

will

 

need: 

 

a) nozzle

 

calibrator

 

or

 

an

 

accurate

 

measuring

 

flask 

b) watch

 

or

 

clock

 

with

 

seconds,

 

or

 

a

 

stopwatch 

c) tape-measure 
d) calculator 

 
NOTE:

 

​​

 

“Chemical

 

 

also

 

refers

 

to

 

liquid

 

fertilizers. 

 

1.

Measure

 

time

 

taken

 

to

 

travel

 

100m

 

at

 

the

 

speed

 

used

 

for

 

spraying 

 

NOTE: 

Maximum

 

Recommended

 

Spraying

 

Speed

 

is

 

12

 

Kph. 

 
2.

Run

 

Sprayer

 

and

 

record

 

output

 

from

 

each

 

nozzle

 

(in

 

mls)

 

for

 

the

 

same

 

time

 

it

 

took

 

to

 

travel

 

100m. 

 
Calculate

 

average

 

flow

 

per

 

nozzle. 

Ie.

 

Add

 

individual

 

nozzle

 

output

 

and

 

divide

 

by

 

number

 

of

 

nozzles. 

 

NOTE: 

Check

 

any

 

nozzle

 

tip

 

that

 

is

 

out

 

by

 

±

 

5% 

Discard

 

any

 

nozzle

 

tip

 

that

 

is

 

out

 

by

 

±

 

10% 

 
3.

Litres/ha

 

=

 

​​

Average

 

Nozzle

 

output

 

(ml/nozzle)

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

x

 

100 

500  

 

4.

Chemical

 

to

 

add

 

to

 

tank 

 
Litres

 

of

 

Chemical

 

​​

 

=

 

​​

 

Water

 

in

 

Tank

 

(L)

 

​​

 

​​

 

​​

 

​​

 

x

 

​​

 

​​

 

​​

 

​​

 

Label

 

chemical

 

rate/ha 

L/ha

 

(application

 

Rate) 

 

 

Y:\Manuals\Current\90024-3-PNozz.DOC

 

​​

 

​​

 

​​

 

Содержание Pressure Nozzle Boom Kit

Страница 1: ...OWNER S MANUAL FOR THE PRESSURE NOZZLE BOOM KIT C Dax Systems Ltd P O Box 1010 145 Harts Road Tiritea Palmerston North Ph 64 6 354 6060 Fax 64 6 355 3199 E Mail sales c dax co nz www c dax com...

Страница 2: ...Y Manuals Current 90024 3 PNozz DOC 2...

Страница 3: ...trained in safety This also applies to equipment that is loaned or rented to someone who has not read the owner s manual and is not familiar with the operation of application equipment NEVER EXCEED TH...

Страница 4: ...r a hat long sleeved cotton overalls and boots If you use pesticides regularly it is a good idea to always wear a respirator to avoid cumulative effect Other protection may be required Check the label...

Страница 5: ...nted Booms Only Boom Height Plumbing 12V Pump Plumbing PTO or Engine Driven Theory of Operation 6 Operation Calibrating your Pressure Nozzle Boom 7 Calibration Chart Select Tip Size 8 Spray Tip Select...

Страница 6: ...ced or dismantled by any person other than a service agent or person authorised by C DAX Systems The warranty does not extend to cover consequential damage repair or replacement of parts due to fair w...

Страница 7: ...t line from the pump in an easily accessible position and install the quick release valve with the 8 5mm hose shank Connect the delivery hose to the boom cut the hose to a length so that it can be con...

Страница 8: ...ed you may need to repeat the spraying which will be wasting your money and time Chemicals are expensive Repeat calibration frequently during the seasons to avoid disappointment To calibrate your spra...

Страница 9: ...g calibration table CALIBRATION CHART NOTES chemical field etc STEP 1 Applicatio n Rate of Chemical litres or kilo per hectare STEP 2 Tank Volume litres STEP 3 Forward Speed KPH STEP 4 Average Nozzle...

Страница 10: ...ax systems endeavours to match the boom output flow to the 12V pump size so there is no need to change the tip size All spray tips supplied by C Dax Systems conform to an international standard for ti...

Страница 11: ...0 UF 02 1 5 0 56 112 84 67 56 48 Yellow 2 0 0 65 130 98 78 65 56 2 5 0 73 146 110 88 73 63 3 0 0 80 160 120 96 80 69 3 5 0 86 172 129 103 86 74 4 0 0 92 184 138 110 92 79 1 0 0 69 138 104 83 69 59 110...

Страница 12: ...ly Check the spray tip patterns for wear replace if necessary Calibrate the boom every 100Ha Lubricate any moving boom parts Check spray hoses for kinks or damage replace if necessary Annually Replace...

Страница 13: ...2 0 76 0 71 1 10 1 02 0 95 0 88 1 35 1 25 1 15 1 08 1 1 1 1 V400 4A 8002 pump 4 20 110UF02 0 53 80 64 50 0 62 0 78 1 0 1 0 1 25 1 6 1 V400 4A 8003 pump 4 70 110UF02 0 59 90 71 59 0 55 0 70 0 85 0 88 1...

Страница 14: ...Y Manuals Current 90024 3 PNozz DOC 14...

Страница 15: ...and diaphragm 10492 3 Diaphragm only 10493 4 Fly nut 10343 5 Swivel clamp Part of 10480 6 Swivel clamp pin Part of 10480 7 O Ring 10299 9 Swivel clamp screw 10497 10 Cap and gasket No tip 10710 12 Noz...

Страница 16: ...en used successfully in N Z sine 1984 and for over 10 years in the U S A Why C DAXOIL Works C DAXOIL wraps up the chemical in an emulsifiable natural vegetable oil This encapsulation is advantageous t...

Отзывы: