7
1502154 Rev D
Maintenance
7-3
General Inspection
Inspect the entire unit for the following each time maintenance and adjustments are done:
■
damaged or missing gaskets (rubber in the base and metal mesh in the lid)
■
loose modules or assemblies
■
missing, open (blown), loose, or misaligned fuses
■
heat damage (burn marks, charred components)
■
water damage
Fuse Shorting Bar (Slug) Replacement
➤
To remove the fuse
1.
Remove the fuse/slug using a fuse puller.
2.
Inspect for the following:
■
fatigue cracks in both leaves of the fuse clips
■
broken connections between the fuse clips and the circuit board
■
heat damage on the circuit board or fuse clips
3.
If damage is evident, replace the damaged power supply. (See
➤
To install the fuse
1.
Use a fuse puller to center the fuse or slug across the fuse clip. Be sure that the metal tips
of the fuse/slug do not extend beyond the fuse guides of the holder on either side.
2.
Apply even, steady pressure to the fuse or slug until both ends snap into the holder
simultaneously.
WARNING
Hazardous voltages are present. Use approved safety equipment and
procedures. Do not energize any station until all other stations in the power supply group
have been installed.
CAUTION
Improper fuse installation can:
■
damage the amplifier
■
fail to power the amplifier
■
fail to distribute through power.
CAUTION
Damaged fuse clips or misaligned fuses can cause heat damage. Do not
force or misalign the fuse when installing.
CAUTION
Ensure that your shorting bar is plated with the same material as the fuse
clips. Differing materials may cause corrosion which may damage the fuse clips.
C-COR slugs are plated with the same material as the fuse clips.
Содержание Flex Max901e
Страница 2: ......
Страница 3: ...Flex Max901e 1GHz Amplifiers Trunks FMTE and Bridgers FMBE 1502154 Revision D...
Страница 10: ...viii Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 20: ...1 1 10 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 56: ...4 4 20 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 102: ...7 7 14 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 142: ...B B 32 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 146: ...C C 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 160: ...D D 14 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 164: ...E E 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 170: ...Index 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 171: ......