1502154 Rev D
Troubleshooting
6-1
C H A P T E R 6
Troubleshooting
This chapter provides procedures that check all operational characteristics of a Flex Max901e that
is suspected of being faulty.
Overview
These procedures check all operational characteristics of a Flex Max901e that is suspected of being
faulty. Troubleshooting flow diagrams are provided beginning on page 6-7.
The following information is required for Forward and Return Field Testing:
■
The operational gain of the amplifier (see C-COR Amplifier Specification Sheets)
■
System Forward and Return High and Low Balancing Carrier levels for the amplifier being
tested (see the System Map or Amplifier Data Sheet
)
If available, historical Amplifier Data Sheets will aid in troubleshooting a faulty amplifier.
Verify the following prior to beginning any test procedure:
■
The amplifier is grounded.
■
All tap outlets, active unused ports, ends of cables, and branch points are terminated with
a 75
Ω
impedance.
■
A true RMS, AC-coupled voltmeter is available for AC voltage measurements. Non-true
RMS AC voltmeters will give up to a 10% higher reading than actual. DC voltage
measurements will not be affected.
Note
Most System Maps list the input and output signal levels at bandedge
frequencies established for 68º F (20º C). If necessary, refer to Calculating Balancing
Carrier Levels on page 5-6 and Temperature Compensation on page 5-6.
Содержание Flex Max901e
Страница 2: ......
Страница 3: ...Flex Max901e 1GHz Amplifiers Trunks FMTE and Bridgers FMBE 1502154 Revision D...
Страница 10: ...viii Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 20: ...1 1 10 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 56: ...4 4 20 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 102: ...7 7 14 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 142: ...B B 32 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 146: ...C C 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 160: ...D D 14 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 164: ...E E 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 170: ...Index 4 Flex Max901e 1GHz Trunk and Bridger Amplifiers 1502154 Rev D...
Страница 171: ......