Wiser Home Controller Installation Instructions
22
4.0 Software
Configuration
You are now ready to configure the Wiser Home Controller and create a
custom project for the customer. The installer can develop the PICED
project for the customer's Wiser Home Controller before arriving at the
customer's home.
Prerequisites
Perform the hardware installation and basic checks found in Section 3.
If you have not already done so, install Clipsal C-Bus Toolkit and PICED
software on a PC using the downloaded versions (refer to Section 1.2).
Bring the PC to the customer site.
Note:
During configuration tasks, the router must reboot several times. Allow at
least 90 seconds after a reboot, and then access the router.
Software Configuration Steps
Step
Tasks to Perform
Refer to
Section
1
Using a browser, configure the Wiser Home
Controller's router. Access the GUI at
192.168.2.1
,
username
is
admin
and password is
admin
.
4.1
2
Use C-Bus Toolkit to verify the connection from the PC
to the customer' C-Bus network and to update the
project. The router is the path to the CNI. The IP
address of the router unit is
192.168.2.1
and the
inline CNI is at port
10001
, (as a point of information,
the CNI has the IP address 192.168.2.2.
4.2
3
Use PICED to create and transfer a custom Wiser
Home Controller project for the customer's home.
4.3
Table 7. Software configuration steps