5
QUESTIONS / HELP?
Call C-Aire at 651.462.3440
SINGLE PHASE STARTER BOX
INSTRUCTIONS
1) Connect to Main Power Lead
2) Tighten ( )
3) Record Amps/Volts on Checklist
(Located in Owner’s Manual on page 14)
TOP VIEW
Main Power Into Here
Main Power
Into Here
Wire to Switch
Ground Wire
Wire From the Motor
CAUTION!
Verify all wires are secure and fasteners
are tightened before connecting power to unit.
Dashed lines represent wires supplied by others.
At installation, the customer is to provide:
Disconnect and branch circuit overcurrent protection and
grounding between the power supply and the electrical
control enclosure in accordance with the National Electrical
Code (NEC), the Canadian Electrical Code (CEC) and / or
any local codes having precedence.
SINGLE PHASE STANDARD MAGNETIC MOTOR STARTER
WITH AUTOMATIC START/STOP CONTROL
PRESSURE
SWITCH
MOTOR
BLK
BLK
BLK
OL
OL
L1
L2
L3
M
T1
T2
T3
MOTOR CIRCUIT
OVERCURRENT
PROTECTION
M
A1
96
A2
95
WIRING DIAGRAM
(For units with Magnetic Starters)