2

DEFINITIONS

 

DANGER: 

Indicates a hazardous situation that, if not avoided, will result in death or serious injury.

 

WARNING: 

Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

 

CAUTION: 

Indicates a situation that will or could cause minor injury or property damage.

GENERAL PRECAUTIONS

 

Read the Owner’s Manual before operating. 

 

DANGER: 

 

Do not use compressed air for breathing air applications.

 

 Beware of high voltage: disconnect lockout/tagout electric supply before servicing.

 

 Ground compressor per codes.

 

WARNING: 

 

Beware of high-pressure air: do not bypass, modify, or remove safety/relief valves.

 

 Beware of hot surfaces: allow unit to cool before servicing.

 

 Do not operate with safety guards removed.

 

CAUTION: 

 

To Reduce the Risk of Electric Shock or Injury, Use Indoors Only.

 

Never operate the compressor near flammable liquids or vapors.

 

 Do not direct the air stream at body.

 

 Drain tank air every day to decrease risk of bursting.

NOTE: 

Per UL 1450:46.17 C-Aire recommends a maximum of 70% duty cycle for its compressors.

Upon receipt, inspect the unit for damage and missing parts. If either is apparent, make notations on the delivery receipt, 
before signing the receipt. Ask the carrier how to file a claim for shipping damages.

If concealed damage is discovered (after receiving the unit), notify the carrier within 15 days of receipt, in writing.

 

WARNING: 

 

Be sure lifting equipment is capable of supporting the weight of the unit.

 

 Lift the unit by the shipping skid only.

 

 Do not walk under or work under the unit while it is suspended.

SELECTING A LOCATION:

C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area, not less than 12 
inches from walls or other equipment.

Provide at least 1,000 cubic feet of fresh air per 5 hp.

Ideal operating temperatures are between 32°F and 100°F.

Avoid excessively humid areas, as moisture may form in the pump, producing sludge and causing moving parts to wear 
prematurely.

SAFETY 

RECEIVING AND INSPECTION

INSTALLATION

(INSTALLATION CONTINUED ON NEXT PAGE)

COMPRESSOR CAPACITY FOR DRY SYSTEMS

 

STANDARD DRY SYSTEM

LOW PRESSURE SYSTEMS

Model #

HP

Tank Size

40 psi

20 psi

10 psi

Light Duty

S260R-LD1-115P

1

1 gallon

260 gal.

520 gal.

1,040 gal.

Light Duty

S261R-LD1-115PD

1

NA

261 gal.

522 gal.

1,200 gal.

Standard Duty S300 SD

1.5

3 gallon

300 gal.

600 gal.

1,200 gal.

Heavy Duty

S175H-HD

1

3 gallon

208 gal.

416 gal.

832 gal.

Heavy Duty

S265H-HD

1.5

3 gallon

305 gal.

610 gal.

1,220 gal.

Heavy Duty

S325H-HD

1.5

3 gallon

372 gal.

744 gal.

1,488 gal.

Heavy Duty

S500 HD

1.5

30 gallon

559 gal.

1,118 gal.

2,236 gal.

Heavy Duty

S750 HD

3

30 gallon

870 gal.

1,740 gal.

3,480 gal.

Heavy Duty

S900 HD

5

30 gallon

925 gal.

1,850 gal.

3,700 gal.

Heavy Duty

S1300HD

5

60 gallon

1,390 gal.

2,780 gal.

5,560 gal.

Heavy Duty

S1700HD

7.5

60 gallon

2,400 gal.

4,800 gal.

9,600 gal.

Содержание S260R-LD1-115P

Страница 1: ......

Страница 2: ...fe LD Light Duty 2 000 hour life SERIES 1 Single Phase 3 Three Phase PHASE 115 Available on S500 and smaller 230 208 230v 460 VOLTAGE P Prewired Power Cord S Prewired Magnetic Starter U 30 40psi Adjus...

Страница 3: ...to decrease risk of bursting NOTE Per UL 1450 46 17 C Aire recommends a maximum of 70 duty cycle for its compressors Upon receipt inspect the unit for damage and missing parts If either is apparent ma...

Страница 4: ...SCHARGE PIPING CAUTION Do not operate unit without inlet air filtration If the air is dirty pipe the filter to a source of clean air Do not install piping with a diameter lower than that of the pump i...

Страница 5: ...electrical controls must be in accordance with NFPA 70 1996 National Electric Code National Electric Safety Code and state and local codes Failure to abide by the national state and local codes may re...

Страница 6: ...o unit Dashedlinesrepresentwiressuppliedbyothers Atinstallation thecustomeristoprovide Disconnect and branch circuit overcurrent protection and grounding between the power supply and the electrical co...

Страница 7: ...rical Code NEC the Canadian Electrical Code CEC and or any local codes having precedence THREE PHASE STANDARD MAGNETIC MOTOR STARTER WITH AUTOMATIC START STOP CONTROL PRESSURE SWITCH MOTOR BLK BLK BLK...

Страница 8: ...95W2 Oil Capacity 2 23QT C Aire Synthetic Compressor Oil Recommended Replacement Parts Air Filter 210 0952 Check Valve BR c 7575 ST Check Valve Breather Pump Serial Tag Check Valve Pressure Gauge Air...

Страница 9: ...y Relief Valve Pressure Switch OFF AUTO Unloader Valve Unloader Valve Safety Relief Valve Pressure Switch Electric Motor Belt Guard Electric Motor Sight Glass Sight Glass specific part numbers Belt Gu...

Страница 10: ...ommended when using synthetic oil The oil drain plug is located at the base of the pump see diagram The oil fill plug is located at the top of the pump header see diagram CAUTION Never remove either o...

Страница 11: ...ION Open the drain valve slowly to release the moisture as pressure in the tank can cause the moisture to expel at very high velocity C Aire recommends installing an automatic tank drain valve EL CRDV...

Страница 12: ...r can be adjusted per the instructions below PULLEY SHEAVE ALIGNMENT AND BELT TENSION COMPRESSOR SHEAVE DOWNWARD DEFLECTION INCHES MOTOR PULLEY DIAMETER SPAN LENGTH DIRECTION OF FORCE APPLIED SETTING...

Страница 13: ...ATION LOSS OF USE LOST PROFITS LOST INCOME WHETHER SUFFERED BY THE BUYER OR A THIRD PARTY HEAVY DUTY SERIES WARRANTY C Aire warrants its compressor pumps from the Heavy Duty Series noted by the HD in...

Страница 14: ...See pressure switch adjustment Reset overload Replace rod Replace complete piston assembly Tighten Replace Valves Tighten Level or shim compressor so all feet touch the floor before tightening down Re...

Страница 15: ...e electrical connections Ensure the correct gauge wire is used based on the Amp draw and distance to the circuit breaker box Distance to circuit box Gauge wire used from box to compressor Amp rating f...

Страница 16: ...em pressure 13 40psi Air Source Dry Pipe Valve No Air Pressure Maintenance Device On 13psi air pressure Off 40psi air pressure Water in system Low Pressure High Pressure System pressure controlled by...

Отзывы: