3
MOUNTING THE COMPRESSOR
!
CAUTION
: Remove the compressor from the shipping packaging before mounting�
FLOOR MOUNTING
Mark hole loca
�
ons
Place unit in chosen loca
�
on,
mark 2 holes and remove
unit.
Floor Mount kits are included
and include 2 anchor bolts, nuts, washers,
and vibration absorption washers.
2
Drill holes
Drill 1.75” deep using a 3/8” masonry drill
bit in the
fl
oor at indicated markings.
3
Install anchor bolts
Tap anchor bolts down to secure while
protec
�
ng bolt threads.
4
Secure Unit
Place unit on anchor bolts, slide on washer
and then loosely thread* nut over bolt.
* Do not
�
ghten nut. Tightening the nut may lead to
stress on the frame causing damage to the unit.
it.u
1
5
Install air
fi
lter assembly
INLET AND DISCHARGE PIPING
!
CAUTION
: Do not operate unit without inlet-air filtration�
If the air is dirty, pipe the filter to a source of clean air�
Do not install piping with a diameter lower than that of the pump intake�
!
CAUTION
: Do not use PVC plastic in the discharge line�
Use hand-welded or threaded steel or copper pipes and cast-iron fittings that are safe for the discharge pressure and temperature�