5
START UP
NOTE
: There is no need to “break-in” your compressor� It has been tested and run at the factory by qualified personnel�
When operating the compressor for the first time, do the following:
1� Perform an inspection of the compressor to ensure there are no obstructions that might interfere with moving parts�
2� Release any remaining air pressure in the manifold by slowly pulling open the safety relief valve (see Parts Identification item 10)�
3� Connect the compressor to the power source (the compressor will start)�
DIGITAL AMD OPERATING INSTRUCTIONS
This Digital AMD has 5 different modes of operation� When it is
powered on, it starts in the
RUN
mode and will display the current
pressure�
RUN
MAX
MIN
PSI
kPa
BAR
24HRS
7 DAYS
STARTS
SETTTINGS
LOCKED
C
P
M
C
Pressing the
M
mode button once will switch it to the maximum
pressure setting, (or the pressure at which the compressor turns
off)� At this point you are able to adjust the maximum/turn off
pressure� When the
MAX
indicator is on, the arrow buttons
can perform a +1/-1 change to the set value� The
compressor will not run in this mode� If the compressor remains
in this mode for 60 seconds with no adjustments, it will
automatically revert back to the
RUN
mode� Range: 10-55 PSI�
RUN
MAX
MIN
PSI
kPa
BAR
24HRS
7 DAYS
STARTS
SETTTINGS
LOCKED
C
P
M
C
Pressing the
M
mode button a second time will switch it to the
minimum pressure mode, this is the minimum pressure the
system will reach before it turns on� At this point you are able to
adjust the minimum/turn on pressure� When the
MIN
indicator is
on, the arrow buttons
can perform a +1/-1 change to
the set value� If the compressor remains in this mode for 60
seconds with no adjustments, it will automatically revert back to
the
RUN
mode� Range: 5-50 PSI�
Note
: the upper and lower
limits have a minimum differential of 5 PSI�
RUN
MAX
MIN
PSI
kPa
BAR
24HRS
7 DAYS
STARTS
SETTTINGS
LOCKED
C
P
M
C
Press the
M
mode button a third time and the
24HRS
indicator
will display the total number of starts in the last 24 hours (The
counter will not measure time if the unit has no power)�
RUN
MAX
MIN
PSI
kPa
BAR
24HRS
7 DAYS
STARTS
SETTTINGS
LOCKED
C
P
M
C
(START UP CONTINUED ON NEXT PAGE)
Содержание S244
Страница 1: ...REV A Dec 15 20 MODELS Fire Protection Air Compressor LL BP MANUAL S244 S600...
Страница 2: ......
Страница 16: ......
Страница 17: ...380 West 1st Street Dresser WI 54009 800 762 2247 651 462 3440 www cairecompressors com...