background image

Important

1. Do not mount the Converter unit onto any metal or UPVC doorframes, as this will

reduce the operating range.

2. Do not immerse either unit in water.
3. Do not mount either unit close to fireplace or expose to high temperature.
4. Do not use different type of batteries, or mix up old and new batteries.
5. Do not leave exhausted batteries in either unit. If leaving the doorbell for long

period, remove the battery from compartments to prevent leakage.

2. Your Wired Bell Push with Converter is ready to use.
In case a Transformer (A/C 8V) is used to power the Wired Bell Push and Wired Door
Chime.
1. Remove the back of the case by pushing in the tab on the bottom with a small, flat

screwdriver.

2. Disconnect the wire that is connected with the Wired Door Chime.
3. Feed the wire via the hole on the back of the Converter, connect the wire to the

terminal positions marked in diagrams below.

4. Snap the front cover of converter back on, then it is ready to use.
Important: Do not connect the Converter unit with any Lighted Bell Push.

SX
Chime
unit

WIRED

CHIME

(Transformer

operation)

4

T

Converter

unit

SX
Chime
unit

WIRED

CHIME

(Transformer

operation)

3

T

Converter

unit

SX
Chime
unit

1

Converter

unit

SX
Chime
unit

WIRED

CHIME

(Battery

operation)

2

Converter

unit

B+C SWITCH
A+C 8V/AC

B+C SWITCH

Wired Bell

Push

Converter unit

Please note that these diagrams are only for
reference as a guide.
Each Wired Chime can be wired differently, so
if you encounter problems, PLEASE CALL THE
HELPLINE NO. 0121 5449499

6. Always use alkaline batteries as these will give longer service and less likely to leak.
7. The Converter and Door Chime units are designed for indoor use only.
8. Please dispose of old, defective batteries in an environmentally friendly manner in

accordance with the relevant legislation.

9. Make sure that no naked flame sources, such as lighted candles, should be placed on

the unit.

10. The unit should not be exposed to dripping or splashing and that no objects filled

with liquids, such as vases, shall be placed on the unit.

11. CAUTION: Replace only with the same or equivalent type of battery that are

recommended by the manufacturer.

12. CAUTION: Danger of explosion if battery is incorrectly installed or replaced.

Trouble Shooting & User Hints

Problem

Chime does not
sound but LED
lights on Converter

Possible Causes

1. Units are out of range

(max. range 100m)

2. Conterter and Chime units

are not on the same digital
code

3. Converter not wired correctly

Suggested Remedy

1. Operate the Chime unit within

the operation range (100m)

2. Re-set the digital code

(see Digital Code Set Up)

3. See wiring diagrams opposite

Chime does not
sound plus no
lights on Conterter
LED

1. Flat Converter battery
2. Wrong polarity of battery in

Converter

1. Change the battery
2. Re-insert battery as internal

marking in right polarity

Chime sounds
without Converter
being pressed

A similar Wire Free Door
Chime product is operating nearby
on the same frequency
digital code

Re-set the digital code
(see Digital Code Set Up)

NOTE: There are no serviceable parts in the unit, do not attempt to repair it.

Specification

A. Converter unit
Power
Consumption

: 1 x 12 volt battery (“A23” - included. Replace with Byron SD-100 model)
: 3.0mA - ON
  0.003mA - OFF

B. Door Chime unit
Power
Consumption

Operating Temperature
Operating Distance
Selectable Digital Code

: 3 x 1.5volt batteries (“C”, UM2 or R14 - not included)
: 100mA - ON
  0.1mA - Stand-by

: -10

°

C to +40

°

C

: 100 metres (320 feet approx.) in open field
: Total sixteen (16) possible digital codes

Wire Free Door Chime Kit with Converter-SX-54

Отзывы: