background image

MAINTENANCE

OPERATOR MANUAL

45

P20PS

46

OM-P20PS2019001-EN

06A29

ANT. MISSING 

06A0

WAITING DATA  

Waiting for data

1.Check if the CAN BUS communication line is connected properly;

2.Check if the bit rate of the communication is consistent;

06A0

EPS NOT ALIGNED

Waiting for data

1.Check if the zero proximity switch is installed properly;

2.Check if the zero proximity switch is correctly selected;

3.Check if the output data of zero proximity switch is correct;

06A0

WAITING FOR TRAC

Waiting for towing controller

1.Check if the CAN BUS communication line is connected properly;

2.Check if the connection line of interlock switch is correct;

3.If the interlock switch is controlled by tiller, set TILLER SEITCH as HANDLE;

06A0

KEYOFF

Key switch voltage low

1.Check if the key switch voltage receives a low voltage pulse when turning on the external 

load;

2.Check if B+ and B- are firmly connected to the controller;

3.If the fault is reported every time the key is turned on, replace the controller;

06A25

ENCODER ERROR 

Encoder fault

The controller detects that two successive speed readings of the encoder differs greatly from 

each other. A normal encoder in the system cannot change speed readings greatly within a 

very short time. Hence, a possible cause for the symptom is that the wires of one or more 

encoders are worn or broken. Check the mechanical and electrical parts of the encoder. 

Another possible for the symptom is electromagnetic interference from the sensor bearing. If 

the symptom is not due to the two causes, replace the controller.

Note: Sometimes manual operations may also cause this fault indicating on the controller. In 

these cases, it is required to turn off power supply and start the forklift again. For example:

1.The forklift suddenly collides with an obstacle so that it is incapable of travelling;

2.The driver applies the brake sharply while the forklift is travelling at a high speed.

06A7

Q LINE SENSOR KO

Step motor Q LINE voltage 

failure

1.Check if the stepper motor cable is intact;

2.Resistance between Q line and B- too small (Approaching 30Ω);

06A6

D LINE SENSOR KO

Step motor D LINE voltage 

failure

1.Check if the stepper motor cable is intact;

2.Resistance between D line and B- too small (Approaching 30Ω);

06A27

GAIN EEPROM KO 

EEPROM memory current 

value is different

Replace the controller;

06A11

DATA ACQUISITION

Data collection

Activation of this fault indicates data acquisition is under way. Wait data acquisition is 

completed.

06A24

MICRO SLAVE KO

Main and slave microprocessor 

detection does not match

1.When using a stepper motor, the direction of the stepper motor detected by the main

microprocessor and slave microprocessor is inconsistent;

2.In the closed-loop control system, the direction of the stepper motor detected by the main 

contactor is incorrect and is inconsistent with the direction of the stepper motor detected by 

the slave contactor;

3.The main contactor did not detect the steering limit position, but it was detected by the

slave contactor;

06A28

CAN BUS KO 

CAN BUS communication fault

1.Check if the CAN BUS communication line is connected properly;

2.Check if the bit rate of the communication is consistent;

3.Check if the CAN communication is open;

4.Check if the CAN communication loop resistance is 60Ω.

06A22

S.P OUT OF RANGE

Output steering potentiometer 

out of range

If a single potentiometer, such as CPOC1 end, is out of range 0.8V-4.2V, it will alarm. When 

the dual potentiometer is selected, the sum of the two sliding ends (CPOC1+CPOC2) is out 

of the range of 4.4V-5.5V and it will alarm. Check the connection of potentiometer.

06A23

F.B OUT OF RANGE

Feedback of steering motor 

encoder out of range

Feedback potentiometer (CPOT connecting to CNB#6) has fault, it will alarm. The range of 

CPOT is out of 0.3V-4.7V, it will alarm. Check if the steering motor encoder is connected 

correctly and whether there is a open circuit;

06A21

MICRO SLAVE

The information on the 

status bus between the main 

microprocessor and slave 

microprocessor is frozen to the 

OXFF value.

The controller should be replaced;

06A19

KM OPEN     

Main contactor of slave 

contactor open

Slave contactor monitors the open of safety contactor of main contactor, and the controller 

needs to be replaced;

06A18

KS OPEN 

Safety contactor of slave 

contactor open

Main contactor monitors the open of safety contactor of slave contactor, and the controller 

needs to be replaced;

06A17

KM CLOSED 

Safety contactor of main 

contactor closed in advance

Slave contactor monitors the advanced close of safety contactor of main contactor, and the 

controller needs to be replaced;

06A16

KS CLOSED 

Safety contactor of slave 

contactor closed in advance

Main contactor monitors the advanced close of safety contactor of slave contactor, and the 

controller needs to be replaced;

Содержание P20PS

Страница 1: ...P20PS OPERATOR MANUAL OM P20PS2019001 EN...

Страница 2: ...P20PS OPERATOR MANUAL OM P20PS2019001 EN...

Страница 3: ...ING Startup and Control Key Switch 18 Emergency Disconnect Switch 18 Fork Carriage and Pedal 19 Tiller 20 Travel Steering and Braking 20 Low Speed Control 22 Fork Lifting and Lowering 22 Horn 23 Emerg...

Страница 4: ...ERATOR MANUAL 3 P20PS 4 OM P20PS2019001 EN Vehicle Maintenance 35 Schematics Hydraulic Schematic 36 Schematic of Electrical System 37 Fault Code Table Fault Code Table 38 OTHER INFORMATION Contact Inf...

Страница 5: ...operated in the environments other than those mentioned in this manual contact with your local BYD dealer first for confirmation Any modification to the forklift is not allowed unless BYD s written c...

Страница 6: ...ations and guide principles such as 1 Operation of industrial vehicle 2 Lane and operative area regulation 3 Diver s right responsibility and standard of behavior 4 Special operation area 5 Daily main...

Страница 7: ...remind the operators of potential risks as well as safety notices Find and read all these decals and signs If the warning decals and signs are missing or difficult to read please contact your local B...

Страница 8: ...General View 1 2 3 6 8 7 9 5 4 10 11 12 13 No Name No Name No Name 1 Load Wheel 6 Display 11 Shield 2 Fork 7 Tiller 12 Front Body 3 Rear Body 8 Emergency Disconnect Switch 13 Pedal 4 Battery Pack Cove...

Страница 9: ...arance m2 mm 25 25 4 34 Aisle width 800x1200mm lengthwise Ast mm 1919 2403 1989 2473 4 35 Turning radius Ast mm 1680 1750 Performance Data 5 1 Travel speed with without load km h 9 12 6 6 5 2 Travel s...

Страница 10: ...rent specification Check the nameplate before operation to confirm the forklift specification 2 When transporting the load it should not exceed the rated loading capacity of the forklift Check and con...

Страница 11: ...nd start the vehicle and the key will automatically return to the on position When the vehicle is powered on for a period of time the vehicle will automatically power off at this time rotate the key t...

Страница 12: ...run 1 0 0 Cannot run 0 0 0 Turtle speed 3km h adjustable Fork carriage 1 Open 0 Retract Pedal 1 Open 0 Retract Person 1 Person on the pedal 0 Person off the pedal P20PS Low speed Put down the fork car...

Страница 13: ...e the tiller to the areas of A1 or A3 to brake Release the accelerator button B to brake when the vehicle speed is 0 apply the brake immediately A1 A2 A3 B Low Speed Control Press the low speed contro...

Страница 14: ...battery level repairing sign low speed sign hour meter and fault code The indicator light indicates low battery level or maintenance condition Name Descriptions 1 Warning Indication When the battery...

Страница 15: ...r the load is placed on the forks keep the mast tilted backwards and raise the forks above the floor 3 During the travelling of the forklift do not tilt the mast forward or try raising the forks to av...

Страница 16: ...ual of the charger to charge the forklift REMA Note 1 If the charge port cover is opened it is impossible to use the stacker To use the pallet truck close the charge port cover 2 The environment tempe...

Страница 17: ...ort vehicle on turtle speed mode Caution 1 Have a supervisor or a second person on site as a lookout 2 Make sure that the ground is strong enough to avoid the transport vehicle sinking into the floor...

Страница 18: ...disconnected from the battery power and press down the emergency disconnect switch Battery status of charge should be around 50 to avoid over discharge or full charge for long term storage 8 Use and...

Страница 19: ...el 1 Check on a daily basis if the wheel fasteners are secured or loose Fasten them if they are loose 2 Take out debris embedded in the tire 3 If the four tires are unevenly worn or the tires are foun...

Страница 20: ...All the components Fastener hydraulic connector structural wear etc Check Driving lift Gear bearing fork wheel brake pad etc Lubricate and clean Hydraulic system Cylinder hydraulic connector and hose...

Страница 21: ...rmal battery voltage or the phase voltage is higher than 50 the battery voltage Possible causes 1 Incorrect phase connection or faulty circuit of the motor Check the motor for incorrect phase connecti...

Страница 22: ...the symptom is not due to the two causes replace the controller Note Sometimes manual operations may also cause this fault indicating on the controller In these cases it is required to turn off power...

Страница 23: ...79 PUMP INC START Oil pump startup sequence fault Incorrect oil pump startup sequence Possible causes 1 The LIFT or TILT switch has already at the ON position before the forklift is started 2 Operatio...

Страница 24: ...or itself for damage 06A48 MOTOR TEMPERAT Motor temperature high 1 If the motor temperature digital switch is turned on or analogue signal exceeds the cutout value then the fault results 2 When motor...

Страница 25: ...ferent Replace the controller 06A11 DATA ACQUISITION Data collection Activation of this fault indicates data acquisition is under way Wait data acquisition is completed 06A24 MICRO SLAVE KO Main and s...

Страница 26: ...tonio Boscato 230 Terminal Intermodal de Cargas TIC CEP 13069 119 CAMPINAS SP Tel 55193514 2551 E mail FORKLIFTSERVICE BYD COM Importer BYD JAPAN CO LTD Address The fifth Yasuda Bldg 5F 2 20 3 Tsuya c...

Страница 27: ......

Отзывы: