Schematic of Electrical System

Fault Code Table

Fault code

Fault

Fault name

Recommended inspection

02A94 NONE 

02A8

WATCHDOG  

Watchdog fault

Turn the key switch to “START”, to see whether the watchdog circuit is activated before the 

software is run. In the standby or operation state, the watchdog signal is invalid (alarm state).

Fault analysis: The watchdog hardware circuit or microcontroller output section is damaged. 

Neither of the two cases is associated with external components. Replace the controller.

02A71 EEPROM  KO

Memory is damaged

Forklift does not travel. Parameter storage becomes faulty so that forklift stops operation. 

Operate the key switch for several times. If the fault still exists, replace the logic card. If the 

fault disappears, parameters previously stored have been replaced by wrong parameters. It is 

imperative to set the parameters again.

02A17 LOGIC FAILURE #3  

Logic card fault #3

Fault with the current protection function of logic card The controller should be replaced.

02A55 LOGIC FAILURE #2 

Logic card fault #2

Fault with the phase voltage feedback hardware circuit in the logic card. Replace the 

controller.

02A54 LOGIC FAILURE #1 

Logic card fault #1

Faults caused by under-voltage or over-voltage protection. In 24V system, the controller 

detects a voltage above 45V or below 9V; In 48V system, the controller detects a voltage 

above 65V or below 11V.

Possible causes:

1.Whether there is short circuit in the circuit system, such as DC-DC, brake coil, etc., or

whether the controller input power supply is in good contact.

2.Whether the battery voltage is over low or over high.

3.Check if the power cable above the terminals such as B+, B, main contactor is tight.

4.Whether the calibration parameter of controller voltage is consistent with the actual voltage.

5.Fault with the hardware circuit protected by over-voltage on the logic card. Replace the

controller.

02A28 PUMP VMN LOW  

Oil pump VMN low

Possible cause: When the motor is turned on, the low-end voltage of MOS tube is higher than 

10% the normal battery voltage, or the phase voltage is higher than 50% the battery voltage.

Possible causes:

1.Incorrect phase connection or faulty circuit of the motor. Check the motor for incorrect

phase connection. Check the motor for current leakage to the ground. Check the motor for 

broken coil.

2.Replace the controller.

02A29 PUMP VMN HIGH

Oil pump VMN high

Possible cause: When the motor is turned on, the low-end voltage of MOS tube is higher than 

10% the normal battery voltage, or the phase voltage is higher than 50% the battery voltage.

Possible causes:

1.Incorrect phase connection or faulty circuit of the motor. Check the motor for incorrect

phase connection. Check the motor for current leakage to the ground. Check the motor for 

broken coil.

2.Replace the controller.

02A72 VMN LOW

VMN low

Possible cause: When the motor is turned on, the high-end voltage of MOS tube is less than 

66% the capacitor voltage, or when the motor is running, the high-end voltage of MOS tube is 

less than the requirement.

Possible causes:

1.Incorrect phase connection or faulty circuit of the motor. Check the motor for incorrect

phase connection. Check the motor for current leakage to the ground. Check the motor for 

broken coil.

2.Check whether the main contactor engages securely. Check the contacts for wear.

3.Replace the controller.

02A31 VMN HIGH 

VMN high

Possible cause: When the motor is turned on, the low-end voltage of MOS tube is higher than 

10% the normal battery voltage, or the phase voltage is higher than 50% the battery voltage.

Possible causes:

1.Incorrect phase connection or faulty circuit of the motor. Check the motor for incorrect

phase connection. Check the motor for current leakage to the ground. Check the motor for 

broken coil.

2.Replace the controller.

02A75

CONTACTOR 

CLOSED

Contacts of  contactor 

get stuck

Before energizing the coil of main contactor, the controller will check whether the contacts 

of main contactor get stuck. Attempt to discharge the capacitor. If the capacitor voltage is 

reduced by 20% the battery voltage, the fault could exist.

1.Check whether the contacts of the contactor get stuck. If so, replace the contactor.

02A19 LOGIC FAILURE #1

Logic fault #1

Check the battery voltage;

2.Check if the ADJUST BATTERY in the controller matches the actual battery voltage.

Содержание P20PS

Страница 1: ...P20PS OPERATOR MANUAL OM P20PS2019001 EN...

Страница 2: ...P20PS OPERATOR MANUAL OM P20PS2019001 EN...

Страница 3: ...ING Startup and Control Key Switch 18 Emergency Disconnect Switch 18 Fork Carriage and Pedal 19 Tiller 20 Travel Steering and Braking 20 Low Speed Control 22 Fork Lifting and Lowering 22 Horn 23 Emerg...

Страница 4: ...ERATOR MANUAL 3 P20PS 4 OM P20PS2019001 EN Vehicle Maintenance 35 Schematics Hydraulic Schematic 36 Schematic of Electrical System 37 Fault Code Table Fault Code Table 38 OTHER INFORMATION Contact Inf...

Страница 5: ...operated in the environments other than those mentioned in this manual contact with your local BYD dealer first for confirmation Any modification to the forklift is not allowed unless BYD s written c...

Страница 6: ...ations and guide principles such as 1 Operation of industrial vehicle 2 Lane and operative area regulation 3 Diver s right responsibility and standard of behavior 4 Special operation area 5 Daily main...

Страница 7: ...remind the operators of potential risks as well as safety notices Find and read all these decals and signs If the warning decals and signs are missing or difficult to read please contact your local B...

Страница 8: ...General View 1 2 3 6 8 7 9 5 4 10 11 12 13 No Name No Name No Name 1 Load Wheel 6 Display 11 Shield 2 Fork 7 Tiller 12 Front Body 3 Rear Body 8 Emergency Disconnect Switch 13 Pedal 4 Battery Pack Cove...

Страница 9: ...arance m2 mm 25 25 4 34 Aisle width 800x1200mm lengthwise Ast mm 1919 2403 1989 2473 4 35 Turning radius Ast mm 1680 1750 Performance Data 5 1 Travel speed with without load km h 9 12 6 6 5 2 Travel s...

Страница 10: ...rent specification Check the nameplate before operation to confirm the forklift specification 2 When transporting the load it should not exceed the rated loading capacity of the forklift Check and con...

Страница 11: ...nd start the vehicle and the key will automatically return to the on position When the vehicle is powered on for a period of time the vehicle will automatically power off at this time rotate the key t...

Страница 12: ...run 1 0 0 Cannot run 0 0 0 Turtle speed 3km h adjustable Fork carriage 1 Open 0 Retract Pedal 1 Open 0 Retract Person 1 Person on the pedal 0 Person off the pedal P20PS Low speed Put down the fork car...

Страница 13: ...e the tiller to the areas of A1 or A3 to brake Release the accelerator button B to brake when the vehicle speed is 0 apply the brake immediately A1 A2 A3 B Low Speed Control Press the low speed contro...

Страница 14: ...battery level repairing sign low speed sign hour meter and fault code The indicator light indicates low battery level or maintenance condition Name Descriptions 1 Warning Indication When the battery...

Страница 15: ...r the load is placed on the forks keep the mast tilted backwards and raise the forks above the floor 3 During the travelling of the forklift do not tilt the mast forward or try raising the forks to av...

Страница 16: ...ual of the charger to charge the forklift REMA Note 1 If the charge port cover is opened it is impossible to use the stacker To use the pallet truck close the charge port cover 2 The environment tempe...

Страница 17: ...ort vehicle on turtle speed mode Caution 1 Have a supervisor or a second person on site as a lookout 2 Make sure that the ground is strong enough to avoid the transport vehicle sinking into the floor...

Страница 18: ...disconnected from the battery power and press down the emergency disconnect switch Battery status of charge should be around 50 to avoid over discharge or full charge for long term storage 8 Use and...

Страница 19: ...el 1 Check on a daily basis if the wheel fasteners are secured or loose Fasten them if they are loose 2 Take out debris embedded in the tire 3 If the four tires are unevenly worn or the tires are foun...

Страница 20: ...All the components Fastener hydraulic connector structural wear etc Check Driving lift Gear bearing fork wheel brake pad etc Lubricate and clean Hydraulic system Cylinder hydraulic connector and hose...

Страница 21: ...rmal battery voltage or the phase voltage is higher than 50 the battery voltage Possible causes 1 Incorrect phase connection or faulty circuit of the motor Check the motor for incorrect phase connecti...

Страница 22: ...the symptom is not due to the two causes replace the controller Note Sometimes manual operations may also cause this fault indicating on the controller In these cases it is required to turn off power...

Страница 23: ...79 PUMP INC START Oil pump startup sequence fault Incorrect oil pump startup sequence Possible causes 1 The LIFT or TILT switch has already at the ON position before the forklift is started 2 Operatio...

Страница 24: ...or itself for damage 06A48 MOTOR TEMPERAT Motor temperature high 1 If the motor temperature digital switch is turned on or analogue signal exceeds the cutout value then the fault results 2 When motor...

Страница 25: ...ferent Replace the controller 06A11 DATA ACQUISITION Data collection Activation of this fault indicates data acquisition is under way Wait data acquisition is completed 06A24 MICRO SLAVE KO Main and s...