BYD COMPANY LIMITED
Rev. 21.12 2018
Document
Installation Manual and User Manual for BYD
Project No.
\
Code
2M SOP0007540
Edition
13
Page
17 / 30
17
BYD ***P6-24/P6C-24
≤
26
BYD ***P6-27/P6C-27
≤
23
BYD ***P6-30/P6C-30
≤20
BYD ***P6-36/P6C-36
≤17
BYD ***M6-36/M6K-36
≤
16
BYD ***P6-30/PHC-30
≤
20
BYD ***M6-30/M6K-30
≤
20
BYD ***P6-30/PHC-36
≤
17
BYD ***P6-30/PHT-36
≤
17
And the electrical characteristics are /- 10% of the indicated
values of Isc, Voc, Pmax under STC.
According to the system voltage (1100V) of the IEC standard.
Under normal conditions, a PV module is likely to experience conditions
that produce more current/voltage than reported at STC. Accordingly,
Isc and Voc must be multiplied by 1.25 (for C-Si or non-C-Si) we
recommend
the maximum number of series connected modules for
each module series as stated below:
Type
The maximum number of
modules in series
BYD*** P6E-18
≤
37
BYD*** P6E-24
≤
28
BYD*** P6E-27
≤
24
BYD*** P6E-30
≤
22
BYD*** P6E-36
≤
19
BYD ***M6-36/M6K-36
≤
17
And the electrical characteristics are /- 10% of the indicated
values of Isc, Voc, Pmax under STC.
According to the system voltage (1500V) of the IEC standard.
Under normal conditions, a PV module is likely to experience conditions
that produce more current/voltage than reported at STC. Accordingly,
Isc and Voc must be multiplied by 1.25 (for C-Si or non-C-Si) we
recommend
the maximum number of series connected modules for
each module series as stated below:
Type
The maximum number of
modules in series
BYD ***P6-18/P6K-18
≤
51
BYD ***P6-24/P6K-24
≤
39
BYD ***P6-27/P6K-27
≤
34