(2) The bypass diode should have a Rated Average Forward
Current at least 10A, and a Rated Repetitive Peak Reverse Voltage of
at least 40V.The diode types are as below:
Type
Maximum DC Blocking Voltage
Maximum Average Forward Current
20SQ045
45V
20A
10SQ050
50V
10A
GF2045MG
45V
20A
SDA2040
40V
20A
(3)For field connections, use minimum 12 AWG
(
E300485 PV
Wire
)
copper wires insulated for a minimum of 90°C,Suggest
using 202 connectors
(
For 1000V
)
/202B connectors
(
For
1100V/1500V
)
.
(4
) The cable must not be bent or crushed on the direct exit of
the cable screw joint include connecter and box. A minimum
bending radius R
≥
4
×
cable diameter must be maintained. The
cable must be routed in a way that tensile stress on the conductor
or connections is prevented. The pictures are as below:
(5)
The maximum number of series connected modules depends
on the system design, the type of inverter used and environmental
conditions. According to the system voltage (1000V) of the IEC
standard. Under normal conditions, a PV module is likely to experience
conditions that produce more current/voltage than reported at STC.
Accordingly, Isc and Voc must be multiplied by 1.25 (for C-Si or
non-C-Si) we recommend
the maximum number of series connected
modules for each module series as stated below:
Type
The maximum number of
modules in series
BYD ***P6-18/P6C-18
≤
34