5.6
Operating environment
Operating environment parameters
No.
Item
Requirement
Unit
Remark
Min.
Typical
Max.
1
Discharging temperature
-10
25
50
℃
2
Charging temperature
-10
25
50
℃
3
Relative humidity
5
95
%
4
Absolute humidity
0.26
25
g/m3
5
Elevation
-
2000
-
m
6
IP level
20
5.7
B-Plus 2.5 address switch introduction
After finished the battery installation, installer should setup battery address through the
“ADDR” switch.
“ADDR” switch introduction:
Function: Communication between battery and BMU. The BMU will communicate with external equipment when using CAN
communication.
Each DIP switch definition:
There are 6 bit switches, keeping it down means
“0”, turn up the switch to “ON” means “1”.
Address: 000000 Address:100000
For example: when two batteries are in use
, “
ADDR
”
setting shows: