22/36
2019/02 - Indice de révision : A - Code : 33290
BWT MINI-HEATER
9.
TROUBLE SHOOTING
9.1
Error code displayed
Fault
Code
Cause
Solution
Ambient air temperature
is too high or too low
P0
The ambient
temperature is outside
the operating range, 11
- 42°C
Controller fault
Wait until the
temperature falls below
40°C or rises above
13°C before restarting.
Replace the controller
Water temperature
sensor error
P1
Water temperature
sensor defective or
short circuit
Replace the water
temperature sensor
Ambient temperature
sensor error
P2
Ambient temperature
sensor defective or
short circuit t
Replace the ambient
temperature sensor
Low pressure protection
EL
Low pressure switch
disconnected or
defective.
Gas leak
Have the device
repaired by a
professional.
9.2
Other malfunctions
Fault
Observation
Cause
Solution
The heat pump does not
start up
Nothing displayed on
the control panel
The heat pump is not
energised
Check the condition of
the cable, the differential
switch and the circuit
breakers
The water temperature
is displayed on screen
No error code
The water temperature
is above or equal to the
set point
The heat pump just
started
Check the set point
selected
Wait for the time-out to
finish (3 minutes)
The heat pump stops in
an untimely manner
The water temperature
is displayed on screen
No error coder
Air circulation is
insufficient
Lack of R32
The fan is defective
Check that air can
circulate freely through
the machine.
Call your supplier for
after sales service.
10.
MAINTENANCE AND WINTERIZING
During winter, or when the ambient air temperature falls below 0°C, drain water from the heat pump to
avoid damage to the titanium heat exchanger caused by freezing of water in the machine. This would entail
cancellation of the guarantee.
From time to time, check that machine gratings are not obstructed with dirt (dust, grass cuttings, pollen
and dead leaves, petals, etc.).
For maintenance interventions or scrapping, contact an approved maintenance centre.
Содержание SHP2.5 ON/OFF
Страница 11: ...Notes 11 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 12: ...Notes 12 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 23: ...Notes 23 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 24: ...Notes 24 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 35: ...Notes 35 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 36: ...Notes 36 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...