19/36
2019/02 - Indice de révision : A - Code : 33290
BWT MINI-HEATER
Installation with valves
Recommended installation (on a by-pass loop)
In the case of installation on a by-pass loop, the isolation valves must be fully open, the regulating valve
should be used to adjust the flow rate through the device to approximately 2 m3/hour.
To connect the heat pump, use a flexible tube with an internal
diameter of 32 mm or 38 mm.
The water inlet tube is marked with blue, the water outlet tube
is marked with red. The unions are double siameter, the 38 mm
diameter cross section is the closest to that of the device.
Place a collar clamp over the free end of the tube.
Push the tube fully onto the corresponding hose tail.
Position the collar clamp so that it is properly seated on the
union.
Содержание SHP2.5 ON/OFF
Страница 11: ...Notes 11 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 12: ...Notes 12 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 23: ...Notes 23 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 24: ...Notes 24 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 35: ...Notes 35 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...
Страница 36: ...Notes 36 36 2019 02 Indice de révision A Code 33290 PISCINE URBAINE BWT myPOOL ...