![BWT Rondomat Duo Series Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/bwt/rondomat-duo-series/rondomat-duo-series_installation-and-operating-manual_2836737010.webp)
36
36
36
36
36
GB
GB
GB
GB
GB
Quick guide to operation
Quick guide to operation
Quick guide to operation
Quick guide to operation
Quick guide to operation
l / h
l / h
l / h
l / h
l / h
Time
Time
Time
Time
Time
Current softened water supply
Current softened water supply
Current softened water supply
Current softened water supply
Current softened water supply
Oper
Oper
Oper
Oper
Operation displa
ation displa
ation displa
ation displa
ation display
y
y
y
y
After-sales service staff
After-sales service staff
After-sales service staff
After-sales service staff
After-sales service staff
only
only
only
only
only
Change language
Change language
Change language
Change language
Change language
Setting the time and date
Setting the time and date
Setting the time and date
Setting the time and date
Setting the time and date
Setting the hardness of
Setting the hardness of
Setting the hardness of
Setting the hardness of
Setting the hardness of
untreated and blended
untreated and blended
untreated and blended
untreated and blended
untreated and blended
water
water
water
water
water
Actuating regeneration,
Actuating regeneration,
Actuating regeneration,
Actuating regeneration,
Actuating regeneration,
column change and
column change and
column change and
column change and
column change and
quick flushing
quick flushing
quick flushing
quick flushing
quick flushing
Selection displa
Selection displa
Selection displa
Selection displa
Selection display
y
y
y
y
The Browse button toggles
The Browse button toggles
The Browse button toggles
The Browse button toggles
The Browse button toggles
between the Operating and
between the Operating and
between the Operating and
between the Operating and
between the Operating and
Selection display
Selection display
Selection display
Selection display
Selection display
Moves cursor,
Moves cursor,
Moves cursor,
Moves cursor,
Moves cursor,
changes entries
changes entries
changes entries
changes entries
changes entries
Moves cursor
Moves cursor
Moves cursor
Moves cursor
Moves cursor
Confirms
Confirms
Confirms
Confirms
Confirms
entries
entries
entries
entries
entries
This column is in
This column is in
This column is in
This column is in
This column is in
operation
operation
operation
operation
operation
Inputs and outputs
Inputs and outputs
Inputs and outputs
Inputs and outputs
Inputs and outputs
The following can be connected to the Soft-Control controller if required:
The following can be connected to the Soft-Control controller if required:
The following can be connected to the Soft-Control controller if required:
The following can be connected to the Soft-Control controller if required:
The following can be connected to the Soft-Control controller if required:
Dosing output
Dosing output
Dosing output
Dosing output
Dosing output
The input and output pulse of the water meter have the same form. Max.
Max.
Max.
Max.
Max. 5
5
5
5
5 V
V
V
V
V, 5 mA DC
, 5 mA DC
, 5 mA DC
, 5 mA DC
, 5 mA DC
Regeneration start
Regeneration start
Regeneration start
Regeneration start
Regeneration start
If the switch connecting terminals 33 and 34 is closed, the unit will regenerate.
Regeneration signal
Regeneration signal
Regeneration signal
Regeneration signal
Regeneration signal
The regeneration signal output (terminals 31 and 32) is short-circuited while the unit regenerates. Max.
Max.
Max.
Max.
Max. 5
5
5
5
5 V
V
V
V
V, 5 mA DC
, 5 mA DC
, 5 mA DC
, 5 mA DC
, 5 mA DC
Pressure switch (optional)
Pressure switch (optional)
Pressure switch (optional)
Pressure switch (optional)
Pressure switch (optional)
If a pressure switch is built into the untreated water pipeline, regeneration is stopped if there is a pressure drop during regeneration and
restarted when there is enough water pressure.