Refilling brine tank
Pressure in system is high
AV04 is closed or PM01 is
defect
35 Water pressure is not releasing during valve test
−
Check that AV04 is open
−
Check AV04 for blockages
−
Check that PM01 is switching and sending signal to PLC
Refilling brine
tank
Pressure in
system is low
AV04 failed to
close
or supply water pressure is
low
36 Water pressure is not building up
−
Check that AV04 is closed
−
Check that AV04 is free from any blockage, that will prevent it from
closing
−
Check for leaks in the hoses or components in the machine
−
Check water supply
−
Check water filter and/or strainer by supply
Refilling brine
tank
Pressure in
system is low
AV02 is open
or AV01
is open or
AV08 is
open
37 Water pressure is not staying high
−
Check that all valves are closed
−
Check that valves are free from any blockage, that will
prevent them from closing
−
Check for leaks in the hoses or components in the machine
Refilling brine tank
Pressure in system is high
AV08 failed to open
38
Water pressure is not releasing during valve test
− Check that AV02 is open
Refilling brine tank
Pressure in system is
high AV08 failed to
open
or system for filling brine
tank is
blocked
39
Water pressure is not releasing during valve test
−
Check that AV08 is open
−
Check for blockages in brine suction filter and connections
Regeneration
Pressure in system is
high AV04 is closed
or PM01 is defect
40
Water pressure is not releasing during valve test
−
Check that AV04 is open
−
Check AV04 for blockages
Check that PM01 is switching and sending signal to PLC
Regeneration
Pressure in system is low
AV07 failed to change flow
direction
41
Water pressure is not building up
−
Check that AV07 has switched
−
Check that AV01 is open
−
Check water supply
−
Check water filter and/or strainer by supply
Regeneration
Pressure in system is
low supply water
pressure is low
42
Water pressure is not building up
−
Check that AV01 is open
−
Check water supply
−
Check water filter and/or strainer by supply
Regeneration
Pressure in
system is low
AV02 is open
or AV01
is open
or AV08
is open
43
Water pressure is not staying high
−
Check that all valves are closed
−
Check that valves are free from any blockage, that will
prevent them from closing
−
Check for leaks in the hoses or components in the machine
Содержание Disinfecton
Страница 1: ...1 BW T Disinfecton On site production of disinfection liquid Installation and Operating manual EN...
Страница 8: ...8 Type Key...
Страница 9: ...9 Product overview Electrical cabinet Hydraulic cabinet...
Страница 27: ...27 Spare part drawings...
Страница 28: ...28 PI diagram...
Страница 29: ...29 Arrangement drawing...
Страница 32: ...32 Declaration of Conformity...