![BWT Disinfecton Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/bwt/disinfecton/disinfecton_installation-and-operating-manual_2836674021.webp)
21
failed to open
or supply water flow is low
Refilling
brine tank
Flow in system
is low AV01
failed to open
or supply water flow is low
05 Water flow is below minimum level.
−
Check that AV01 and AV04 are open
−
Check that AV01 and AV04 are free from any blockage, that
will prevent them from closing
−
Check water supply
−
Check water filter and/or strainer by supply
−
Check for leaks in the hoses or components in the machine
Refilling
brine tank
Flow in system
is high AV04
failed to close
or AV02 is
open
or AV08 is open
06 Water flow continues during closing operation
−
Check that AV04, AV02 or AV08 are closed
−
Check for leaks in the hoses or components in the machine
Refilling brine tank
Flow in system
is high AV01 is
open
or AV02 is
open or
AV04 is
open
or AV08 is open
07 Water flow continues during closing operation
−
Check that all valves are closed
−
Check for leaks in the hoses or components in the machine
Refilling brine tank
Flow in system
is high AV01 is
open
08 Water flow continues during closing operation
−
Check that AV01 is closed
−
Check that AV08 is free from any blockage, that will prevent it from
closing
Refilling
brine tank
Flow in system
is low AV01
failed to open
or supply water pressure is
low
09 Water flow is below minimum level.
−
Check AV08 is open
−
Check that AV08 is free from any blockage, that will prevent it from
closing
−
Check water supply
− Check water filter and/or strainer by supply
Regeneration
Flow in system
is low AV01
failed to open
or supply water flow is low
10 Water flow is below minimum level.
−
Check that AV01 and AV04 are open
−
Check water supply
−
Check water filter and/or strainer by supply
Regeneration
Flow in system
is low AV01 is
closed or
AV04 is
closed or
supply water flow is low
11 Water flow is below minimum level.
−
Check that AV01 and AV04 are open
−
Check water supply
−
Check water filter and/or strainer by supply
Содержание Disinfecton
Страница 1: ...1 BW T Disinfecton On site production of disinfection liquid Installation and Operating manual EN...
Страница 8: ...8 Type Key...
Страница 9: ...9 Product overview Electrical cabinet Hydraulic cabinet...
Страница 27: ...27 Spare part drawings...
Страница 28: ...28 PI diagram...
Страница 29: ...29 Arrangement drawing...
Страница 32: ...32 Declaration of Conformity...