6.1 Technical data BWT bestaqua 6,12,18
Note:
The nominal flow is calculated with following drinking water conditions:
*1)
7ATER¬INLET¬TEMPERATURE¬ª#¬SALINITY¬AS¬.A#L¬MAX¬¬MGL
, Primary pressure inlet 3.5bar and a permeate yield
of 40%. During operation, the actual nominal flow may deviate slightly from the flow indicated in the table due to
fluctuations of the inlet water quality, the flow pressure and the flow continuity.
*2)
&OR¬NORMAL¬OPERATION¬THE¬MANUFACTURER¬RECOMMENDS¬THE¬INLET¬OF¬SOFTENED¬FEED¬WATER¬WITH¬A¬HARDNESS¬LOWER¬THAN¬ªD(
Technical data BWT bestaqua 6,12,18
BWT bestaqua (vertical)
BWT bestaqua 6
BWT bestaqua 12
BWT bestaqua 18
Nominal capacity
*1)
(output flow rate)
l/h
60
120
180
Salt retention rate
%
> 95
> 95
> 95
Permeate output/yield (WCF)
*2)
%
40 ... 60
40 ... 60
40 ... 60
Feed water flow (inlet)
l/h
t
100 ... 150
t
200 ... 400
t
267 ... 533
Concentrate flow (drain)
l/h
t
40 ... 90
t
80 ... 280
t
107 ... 373
Feed water pressure
bar
2.0 … 6.0
2.0 … 6.0
2.0 … 6.0
Feed water, ambient temperature (min./max.)
ª#
5 ... 30 / 5 ... 40
5 ... 30 / 5 ... 40
5 ... 30 / 5 ... 40
)RON¬AND¬MANGANESE¬&E-N
mg/l
< 0.05
< 0.05
< 0.05
Silica (SiO
2
)
mg/l
< 15
< 15
< 15
Salt level, Total Dissolved Solids (TDS)
mg/l
< 500
< 500
< 500
Silt Density Index (SDI)
%/min
< 3
< 3
< 3
Oxidants
mg/l
< 0.05
< 0.05
< 0.05
Protection class
IP
54
54
54
Electrical connection / fuse protection
V/Hz/A
230 / 50 / 10
230 / 50 / 10
230 / 50 / 10
Electric power consumption (operation / standby)
W
375 / < 3
375 / < 3
475 / < 3
Type of valve
230VAC
230VAC
230VAC
Standard of connector (grounded PE mains plug)
Three-pin “CEE7“
Three-pin “CEE7“
Three-pin “CEE7“
Feed water, permeate, concentrate connection
inch/inch/mm
3/4“ / 3/8“ / 8
Dimensions: Width, depth, height (W x D x H)
mm
230 x 250 x 380
230 x 335 x 380
230 x 425 x 380
Weight
kg
17
21
24
Order No. (BWT water + more GmbH / AT)
821501
821502
821503
H
D
BWT bestaqua 6,12,18
W