GasAlertMicro
Users Manual
Model No.
Description
Qty
ft./0.3 m probe
GA-TPROB6
Telescopic Sample Probe (6.5
ft./2 m)
1
M2437K
Battery lock screw, kit of 10
(applicable only for –UK, -EU and
–AU detectors)
1
*Add suffix (-UK) for United Kingdom mains plug, (-EU) for
European mains plug, (-AU) for Australian mains plug.
Specifications
Instrument Dimensions
:
6 x 10 x 3.3 cm (2.4 x 4.0 x 1.3 in.)
Weight:
211 g (7.4 oz.)
Operating Temperature:
-20 °C to +50 °C (-4 to +122 ºF)
Storage Temperature:
-20 °C to +50 °C (-4 to +122 ºF)
Operating Humidity:
5% to 95% relative humidity
(non-condensing)
Operating Pressure:
95 to 110 kPa
Alarm Setpoints:
May vary by region and are
user-settable.
Detection Range:
CO: 0-500 ppm in 1 ppm increments
H
2
S,SO
2
: 0-100 ppm in 1 ppm increments
O
2
: 0-30% in 0.1% increments
Combustibles: field settable for:
0-100% LEL in 1% LEL increments or
0-5.0% v/v methane in .1% increments
Sensor Type:
H
2
S/CO: Twin plug-in electrochemical cell
O
2
,SO
2
, H
2
S, CO Single plug-in electrochemical cell
Combustibles: Plug-in catalytic bead
O
2
Measuring Principle:
Capillary controlled concentration
sensor
Alarm Conditions:
TWA Alarm, STEL Alarm, Low Alarm,
High Alarm, Multi-Gas Alarm, Sensor Alarm, Low Battery