GasAlertMicro
User Option Menu
Pass Code Protection
The detector is shipped with Pass Code Protection off. Pass
Code Protection prevents the user access to the User Option
Menu and the Calibration menu (after Auto Zero). The key
icon is lit on a pass code protected unit.
To activate or deactivate Pass Code Protect
Enter the
then press
C
when the screen
displays
PASS Lock
.
The screen advises Pass Code Lock protection is
On
or
Off
and beeps 2 times.
Pass Lock ON
Pass Lock OFF
To enter the pass code
Note:
Pass Code is provided separately.
If the detector is pass code protected, the display advises:
Unit Locked.
Enter the correct 3-digit code and press
C
to confirm entry.
Note:
The correct factory Pass Code must be entered within
10 seconds or the detector returns to normal operation.
Unit
Locked
Please Enter
Pass Code
Enter
Code
Pass code not entered or entered incorrectly
No code entered or
incorrect code entered and
confirmed.
•
Beeps
•
Returns to normal operation
Code entered but not confirmed.
•
Beeps
•
Returns to normal operation
17