BW Technologies GasAlertClip Extreme Скачать руководство пользователя страница 3

GasAlertClip Extreme English Instruction Sheet 

D2139/5 Page 3  

Trimmed and folded dimensions: 4.125 (w) x 5.875 (h)  

 

 

 

Alarms 

Display

Audible

Alarm 

Visual 

Alarm 

Vibration 

Alarm 

Low Gas Alarm 

 

 

One slow 
beep every 
second 

One slow 
flash every 
second 

One slow 

vibration 
every second 

High Gas Alarm 

 

 

Two fast 
beeps every 
second 

Two fast 
flashes every 
second 

Two fast 

vibrations 
every second 

Life-Ending Alarm 

 

 

Eight slow 
beeps per 
minute 

Eight slow 
flashes per 
minute 

Eight slow 

vibrations 
per minute 

Note:

 

When the gas level returns to the acceptable range, the gas alarm 

stops.

 

The life of the battery decreases rapidly when in alarm conditions. 

The battery life-ending alarm occurs when the battery life-remaining 
clock displays 0 hours. The detector will continue to operate for 8 
hours before automatically deactivating. 

Maximum Gas Exposure 

The detector records the maximum gas exposure that is in alarm and begins 
calculating the number of hours from when the maximum exposure 
occurred. 

For each new exposure greater than the current maximum exposure, the 
detector resets the maximum gas exposure to the new level and resets the 

hours

 to 

0

. After 24 hours of gas readings in the acceptable range, the 

detector resets both values to 

0

Viewing the Maximum Gas Exposure 

Press 

C

 within 24 hours of receiving a gas alarm. The LCD displays the 

following: 

The low and high alarm setpoints. 

               

 

 

If a maximum gas exposure has occurred within the last 24 hours, the 
maximum gas exposure screens display. 

               

 

 

 

For exposures beyond the detection range, over limit (

OL

) displays. 

 

Performing a Self-Test 

When

 Test

 displays, the self-test must be performed. 

 

 

The self-test is activated prior to any other function. Press 

C

 to initiate. 

Note: The self-test must be performed in an atmosphere that is free of 

background gas. 

After a self-test is performed, wait 30 seconds before using to ensure 
the detector accurately detects gas. 

To perform a self-test, press and hold 

for approximately 1 second. 

Confirm that the following tests are performed. 

1. 

The detector emits one beep, one flash, and one vibration. 

2. 

All LCD elements display. 

3. 

Test

 flashes while the sensor integrity and battery life are tested. 

4. 

The low and high alarm setpoints display. 

5. 

If an alarm has occurred in the last 24 hours, the LCD displays the 
maximum gas exposure value and the hours that have lapsed since 
the exposure. 

6. 

Prn 

and 

 flash. 

Note: If 

 

C

 is pressed when the self-test pass 

(

u

)

 

icon displays, steps 1-3 

will be bypassed. 

For information regarding a self-test pass or fail, refer to the 

Self-Test Pass

 

and 

Self-Test Fail

 