background image

© 2012 BW TECHNOLOGIES BY HONEYWELL. ALL RIGHTS RESERVED.

2 OR 3 YEAR GAS DETECTOR

50104153-003/05-2012

GasAlert Clip Extreme

The GasAlertClip Extreme 2 or 3 year gas detector (“the detector”) is a 
personal safety device that warns when hazardous gas exceeds factory 
set alarm setpoints. The detector stores and transmits gas alarm event 
data. It is your responsibility to respond properly to the alarms.

Gases Detected

Oxygen (O

2

)

Percent by volume (%)

Carbon monoxide (CO)

Parts per million (ppm)

Hydrogen sulfide (H

2

S)

Parts per million (ppm)

Sulfur dioxide (SO

2

)

Parts per million (ppm)

Safety Information—Read First

Warning:

 Substitution of components may impair Intrinsic Safety.

Warning:

 Bump test the O

2

 sensor before each day’s use to confirm its 

ability to respond to gas by exposing the detector to a gas concentration 
that exceeds the alarm setpoints. Manually verify that the audible and 
visual alarms are activated. 

 

ƒ

Do not activate the detector after the date on the package.

 

ƒ

This product is a gas detector, not a measurement device.

 

ƒ

Perform a self-test each day prior to use.

 

ƒ

Ensure the sensor grill is free of dirt, debris, and is not obstructed.

 

ƒ

Calibrate and/or bump test the detector in a normal atmosphere 
(20.9% O

2

) that is free of hazardous gas.

 

ƒ

Periodically test the response of the sensor to gas by exposing the 
detector to a target gas concentration that exceeds the low alarm 
setpoint. Manually verify that the audible and visual alarms are 
activated.

 

ƒ

Periodically calibrate the GasAlertClip Extreme  
oxygen (O

2

) detector.

c e

 Recycling

This instrument contains a lithium battery. Do not mix with the solid 
waste stream. Spent batteries should be disposed of by a qualified 
recycler or hazardous materials handler.

About This Instruction Sheet

Title

GasAlertClip Extreme Instruction Sheet

Description

This Instruction Sheet is a reference for the 
activation, operation and maintenance of 
the GasAlertClip Extreme 2 or 3 year gas 
detector.

Part Number

50104153-003

Release Date

05-2012

At a Glance

Audible 

alarm

Alligator  

clip

Infrared  

download port

Liquid crystal 

display(LCD)

Sensor and  

sensor grill

LED visual 

alarms

Pushbutton

LCD and Elements

Self-test status

High and low alarm setpoints

Data transmission

Maximum exposure in alarm

Gas type

 

Alarm condition

Detector life-remaining indicators

Months-days-hours since last 
maximum gas exposure alarm

Pushbutton Functions

Activate detector

Press and hold 

for 5 seconds

Perform self-test

Press and hold 

for 1 second when LCD 

displays 

Test

Calibrate oxygen 
sensor

Press and hold 

for 3 seconds

Perform auto zero

Press and hold 

for 3 seconds

View maximum gas 
exposure

Press 

within 24 hours of a gas alarm

Transmit data

Press 

when LCD displays 

Prn

 and 

 

Display gas alarm 
setpoints

Press 

C

 during normal operation