21
Goal achieved: Both weighing facilities are calibrated to one another.
By entering
OK
, you are confirming the process and going back to the main menu.
1
2
Now enter the reference
weight that you then enter in
the feeder mixer wagon. Click
on the empty field to do this.
A keyboard field now opens
where you can enter the
value of the sample weight (in
this case 1,790 kg). Confirm
the entry with
OK
.
Place the sample weight (in
this example 1,790 kg) in the
feeder mixer wagon. Then
wait until
Scale Output –
Millivolt
is stable (only
changes in the fourth decimal
place) and press the button
Calibrate
.
You can save the calibration
via
Save
.
Содержание Dairy Feeder
Страница 13: ...13 After selecting the transceiver box select Next Entering a password is not required Now select Yes ...
Страница 14: ...14 Select the transceiver box Dairy Feeder XXXXXXXX DairyTuner single Dairy Tuner V2S ...
Страница 16: ...16 Select COM 0 or COM 9 and deselect Secure connection the tick must disappear Now press Finish 1 2 3 ...