central vacuum cleaner
The motor does not start
1. If the display on the unit is off, the power supply is NOT OK.
Check the 230 V socket for voltage.
2. If the display on the unit is on, the power supply is OK.
Start the BVC central vacuum cleaner by pushing the POWER button
If the motor does not start, the motor is defective.
Please contact your local BVC partner.
3. If the display on the unit is on, the power supply is OK.
Start the BVC central vacuum cleaner by pushing the POWER button.
If the motor can be started, the problem can either be caused by the
low-voltage transformer, the relay, the low-voltage installation or the
handgrip on the suction hose.
Please contact your local BVC partner or BVC EBS Distribution GmbH.