background image

3

!

   

WARNING

              

Failure

 to comply with the following warnings  

   

  may result in 

personal injury

 as well as 

      

  

property damage

.

     

  • Study, understand, and follow all instructions 

     

     provided with and on this device before use.

        

  

• The user must be a qualified operator familiar 

with the correct operation, maintenance, and use of rams.

     

 

              Wear protective gear when  

   

 

              operating hydraulic equipment.

   

    This device is 

NOT

 suitable for use as 

support

 

   

    device! As the load is lifted, use blocking and 

 

    cribbing to guard against a falling load. Stay  

 

     clear of a lifted load before it is properly supported. 

Never rely on hydraulic pressure to support a load.

   

 

   

Crush Hazard

. Keep hands and feet

   

 

   away from ram and workpiece

   

 

   during operation.

   

  • Do not exceed rated capacity of the ram or

     

    any equipment in the system. The ram is

 

    designed for a max. pressure of 10,000 psi. 

• Do not connect a ram to a pump with higher 

   pressure rating. 

• Do not subject ram to a shock loads, a load 

  dropped suddenly, causing the system pressure to 

  exceed rated pressure.

 

  The system operating pressure must not exceed

  

 the pressure rating of the lowest rated component

                 the system. Install a pressure gauge or other load 

measuring instrument to monitor the operating pressure. Burst 

hazard exists if hose, connection or any other component in 

the system exceed its rated pressure.

 

  Avoid damaging hydraulic hose. Do not allow

 

  hose to kink, twist, curl, crush, cut or bend so

 

  tightly that fluid flow within the hose is blocked or

reduced. Periodically inspect the hose for wear. 

  

 

  Do not pull, position or move ram setup by

 

  the hose. Use carrying handle or other means

 

  of safe transport.

 

  Do not handle pressurized hoses. Never attempt

 

  to grasp a leaking pressurized hose. Ensure to

 

  release the system pressure before disconnecting 

hydraulic hose or connections. 

 

  Hydraulic fluid can ignite and burn. Keep 

 

  

hydraulic equipment away from flames and 

 

  heat. Excessive heat will soften seals, resulting in 

fluid leaks. Heat also weakens hose materials.   

 

       

   

 

  

 

  Ram must be on a stable base which is able

 

  to support the load while pushing or lifting. Use

 

  shims, friction material or constrains to prevent 

slippage of the base or load. Ensure ram is fully engaged 

into/onto adapters, extension accessories. 

 

  Center load on ram. Distribute load evenly

 

  across the entire saddle surface. Do not 

 

  off-center loads on a ram. The load can tip 

 

  or the ram can “kick out”.

  

 

  Never try to disassemble a hydraulic ram,

 

  refer repairs to qualified, authorized personal.

 

   Contact BVA Hydraulics tech service for authorized 

service center.

 

       Do not subject hose to sharp objects or

 

       heavy impact.

 

  Hose material or seals must not come in 

 

  contact with corrosive materials such as 

 

  battery acid, creosote-impregnated objects 

and wet paint. Never paint a coupler or hose.

 

  • No alteration shall be made to the ram.

 

  • Use only factory authorized fasteners,  

      

 

     accessories and hydraulic fluid.

Heavy

!

  

ADVERTENCIA

• Leer, comprender, y seguir las instrucciónes antes de utilizar el aparato.

• El manual de instrucciónes y la información de seguridad deben estar comunicado en lengua del operador antes 

del uso.

• No seguir estas indicaciónes puede causar daños personales o materiales.

Содержание J50040

Страница 1: ...816 448 2142 E mail sales bvahydraulics com Website www bvahydraulics com Max Operating Pressure 10 000 PSI Max Operating Pressure 8 000 PSI Model J50040 Model J50100 J50040 M0_042016 This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death ...

Страница 2: ...rohibited Use only those adapters and attachments provided and approved by the manufacturer NOTICE When extension tubes and or offset attachments are used the rated capacity is always reduced by 50 for each tube or offset attachment connected See Parts Section for identification of offset attachments BEFORE USE 1 Before using this product read the owner s manual completely and familiarize yourself...

Страница 3: ...iodically inspect the hose for wear Do not pull position or move ram setup by the hose Use carrying handle or other means of safe transport Do not handle pressurized hoses Never attempt to grasp a leaking pressurized hose Ensure to release the system pressure before disconnecting hydraulic hose or connections Hydraulic fluid can ignite and burn Keep hydraulic equipment away from flames and heat Ex...

Страница 4: ...Stretch Flat Base Male Connector Ram Combination Head 900 Extension Tube iii Horizontal Push with Extension Serrated Saddle Ram Male Connector Flat Base i Vertical Push ii Horizontal Push Flat Base Male Connector Ram Rubber Head 100 100 25 B Spread i Vertical Spread ii Horizontal Spread iii Hydraulic Spreader Ram Toe Ram Extension Tube Flat Base Ram Toe Ram Plunger Toe Hydraulic Spreader 25 25 0 5...

Страница 5: ...t first wrapping the jaws of such tool with rags or similar padding How to bleed air from system 1 Place pump at a higher elevation than the hose and ram as shown in figure 3 below 2 Operate pump to fully extend and retract the ram 2 or 3 times The objective is to force the air bubbles up hill and back to the pump reservoir 3 To bleed the air from pump reservoir simply open the oil filler screw Re...

Страница 6: ...r Contact service center Ram move slower than normal Loose connection or coupler Restricted hydraulic line or fitting Pump not working correctly Ram seals leaking Tighten connection or coupler Clean and replace if damaged Check pump s operating instructions Contact service center Ram responds to pressurized fluid but system does not maintain pressure Overload condition Pump malfunctioning Ram seal...

Страница 7: ...00 lbs 0 998 in 5 010 psi where F Force Load lbs P Hydraulic working pressure psi and A Ram effective area in Example2 Model J50100 operating at 6 000 psi will generate what force Force 6 000 psi x 2 411 in2 14 466 lbs Load lbs Pressure of 4 Ton Ram where A 0 998 in2 psi Pressure of 10 Ton Ram where A 2 411 in2 psi 1 000 1 002 415 2 000 2 004 830 3 000 3 006 1 244 4 000 4 008 1 659 5 000 5 010 2 0...

Страница 8: ... Extension Tube 8 1 2 1 4 F040 41300 000 Extension Tube 6 1 8 1 5 F040 41400 000 Extension Tube 3 1 6 F040 41600 000 Male Connector 1 7 F040 40001 000 Wedge Head 1 8 F040 40003 000 Serrated Saddle 1 9 F040 44000 000 Flat Base 1 10 F040 40005 000 Plunger Toe 1 11 F040 40004 000 Ram Toe 1 12 F040 43000 000 Rubber Head 1 13 F040 40002 000 Combination Head 1 14 F040 42000 000 Hydraulic Spreader 1000 L...

Страница 9: ...rence of location and position in the assembly sequence MODEL J50040 Maintenance Kit Service Parts SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 448 2142 E mail sales bvahydraulics com Website www bvahydraulics com 2 1 3 4 5 6 7 8 26 19 18 16 9 10 11 12 13 14 15 20 22 23 21 25 24 ...

Страница 10: ...00 000 Extension Tube 10 1 4 F100 41400 000 Extension Tube 4 1 5 F100 41500 000 Male Connector 1 6 F100 40002 000 Wedge Head offset 1 7 F100 40004 000 Serrated Saddle 1 8 F100 40001 000 Flat Base 1 9 F100 40006 000 Plunger Toe offset 1 10 F100 40005 000 Ram Toe offset 1 11 F100 42000 000 Rubber Head 1 12 F100 42003 000 Combination Head 1 13 F040 42000 000 Hydraulic Spreader 1000 Lbs Capacity 1 14 ...

Страница 11: ...ference of location and position in the assembly sequence MODEL J50100 Maintenance Kit Service Parts SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 448 2142 E mail sales bvahydraulics com Website www bvahydraulics com 1 2 3 4 5 6 7 24 20 22 19 21 16 14 8 9 10 11 12 13 17 15 18 23 ...

Страница 12: ... Hydraulics product fails due to material defect in workmanship you may contact SFA for disposition In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement of the defective product Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss whatsoever THIS WARRANTY IS LIMITED ...

Отзывы: