![Buyers SnowDogg EXII Series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/buyers/snowdogg-exii-series/snowdogg-exii-series_owners-manual_2836077024.webp)
24
V BLADE CONTROLLER DIAGNOSTICS
Diagnostic Mode
If this controller detects an issue with the snowplows wiring
system, the indicator light will blink Red 3 times repeatedly.
To determine the issue, go to the Diagnostic Mode. To enter
Diagnostic Mode (turn vehicle’s ignition ON):
1.
Turn the control OFF.
2.
Press & Hold the UP button, then Press & Release the
ON/OFF button. Then, release the Up button.
3.
You are now in Diagnostic Mode (Channel 1) & all outputs
are OFF (the plow will only function during the “short” test).
Blue Indicator Light
• A long blink indicates a starting point for the selected
channel.
Green Indicator Light
• Blinks the number of the selected channel.
Red Indicator Light
• Blinks 4 times to indicate the selected channel is open
(broken).
• Solid (in “short” test) indicates the selected channel is
shorted.
Short test
When you are in any channel, you can test to see if that
channel is shorted by pressing and holding the UP button
(Warning: The plow can move). If, while holding the UP
button, the indicator light shows solid Red, that channel has
a short.
Diagnostic Mode Button Configuration
RIGHT = Increase channel #
LEFT = Decrease channel #
UP = Turns ON selected channel (short test)
ON/OFF = Exit Diagnostic Mode