1. FOREWORD
EN
16
1.3
INTENDED USE
The models described in this manual were designed
and manufactured for intermittent use with a
maximum service factor of 30 % (e.g. 3 minutes of
work and 7 minutes of rest), in optimal environmental
conditions (max temp. 35°C).
Compliance with these instructions and the
maintenance intervals planned will allow good
operation of the product over time.
1.4
GROUND CONNECTION
The compressor is equipped with double insulation.
It does not require ground connection.
Any repairs must only be carried out by a qualified
technician.
1.5
USE OF EXTENSION CABLE
Only use extensions with a plug and ground
connection.
Do not use extension cables that are damaged or
squashed. An under-rated cable will cause a drop in
line voltage resulting in loss of power and overheating.
The extension cable must have a section in proportion
to its length.
Volt / ph
220-230/1
110-120/1
HP
kW
mm² (max.
20 m)
mm² (*)
1,5
1,1
1,5
2,5
WARNING
Avoid electrical shock hazard. Never use this
compressor with a damaged or frayed electrical cord
or extension cord. Inspect all electrical cords regularly.
Never use in or near water or in any environment
where electric shocks are possible.