8
Scheduling device maintenance has to consider the degree and circumstances of device use. Considerate use
and preventive maintenance help prevent needless defects and malfunctions. Perform checks as per standards
and law in force. Only workers with adequate electrical engineering qualifications may carry out any jobs on
the device.
WARNING!!
Any handling of the power supply, including maintenance, requires its disconnection from the power line. To
prevent injuries, always disconnect the power cable and wait at least 10 minutes before removing the casing.
Discharge the capacitor circuits before any further work.
Periodic maintenance includes cleaning the device every half a year:
1. Disconnect the device plug from the socket and wait at least 10 minutes (the capacitors inside the
device will discharge). Then remove the upper device casing.
2. Clean all dirty power electric connections and tighten any loose ones.
3. Clean the internal device parts (coolers in particular) to remove dust and dirt – for example using a
soft brush and vacuum cleaner.
4. The upper casing has to be earthed – remember to connect the yellow-and-green earthing wire before
screwing it on.
5. After maintenance, carry out safety measurements as per standards in force.
Note: Never use solvents or thinners (e.g., acetone), because they may damage insulation, plastic parts and
lettering on the front panel!!
The device has to be stored in a clean and dry room. Protect the device from rain and direct sunshine and
freeze.
After heating completion, leave the device switched on for 10 more minutes - it will be cooled down by fans
until it is cold, then it deactivates the fans. After that, turn it off using the master switch and disconnect it from
the power line.
If you disconnect the device immediately, leave it and all the working coils to cool down for at least 15 minutes.
1. Unless otherwise specified, the warranty period for devices is set by the manufacturer at 12 months
from the date of sale to the buyer . The induction burner is subject to a 6-month warranty period.
Consumables such as extenders, coils, etc. are subject to a 3-month warranty period.
2. When making a claim for warranty repair, the warranty certificate has to be shown; it is only valid if it
bears the date of sale, serial number, stamp of the shop and the seller’s signature, confirming proper
demonstration and explanation of the device features.