14
This is the initial device status, which allows turning the encoder to set the desired heating power or
temperature, depending on the mode selected:
-
Controlled power mode (CP), indicator lamp glows red
– the user sets the desired heating power in
% of maximum heating power and the device automatically adjusts the required parameters to
maintain the set power.
-
Controlled magnetic field mode (CF), indicator lamp glows green
–
the user sets the desired field
intensity in % of maximum field intensity and the device automatically maintains the set field intensity.
The indicator lamp starts flashing during the heating and the display shows the current readings of power
output in kW.
The desired heating mode can be set in the settings or switched by pressing and holding down the encoder –
the display shows the corresponding mode name CP/CF and the indicator lamp changes colour.
Press the encoder to move to further device parameter settings, such as the heating timer, etc.
Note: If the power is controlled remotely, the letters “rc” are displayed for 3 sec when turning the encoder.
Indicator lamp
Status
Red
Heating power setting in %, mode CP
Red, flashing
Power reading in kW during the heating
Green
Magnetic field intensity setting in %, mode
CF
Green, flashing
Power reading in kW during the heating
The timer makes it possible to automatically stop heating after a set amount of time, enabling accurate
dosing of energy (heat) introduced to the material, e.g., for spot or repeated heating to a set temperature.
Press the encoder repeatedly until the
TIMER indicator lamp glows red
. Turn to set the desired heating
time in seconds or deactivate the timer by selecting “OFF“.
If the timer is set, then the indicator lamp glows green
when the heating starts, and if the heating is
stopped by the timer, the indicator lamp starts flashing green
and the display shows the letters “OFF”
once the button is released. Releasing the button stops the heating immediately.
Note: Press the encoder to enter pre-heating/program settings (see following chapter). To exit to power
settings immediately, press and hold down the encoder.