![BUTSIR ATRIO Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/butsir/atrio/atrio_user-manual_2835893027.webp)
27
TROUBLESHOOTING
If you cannot solve the problems according to one of the solutions mentioned, please contact us
through our website: www.butsir.com, write an email to [email protected], phone: +34 936
620 680 or contact your dealer or distributor.
PROBLEM
CONDITION
SOLUTION SUGGESTED
Burner won’t
light
Control knob is not in Maximum
position (big flame).
Turn control knob in Maximum position (big
flame).
LPG cylinder valve is closed /
Empty.
Open the valve / Replace LPG cylinder with
a new one.
Blockage in the injector.
Clean or replace injector.
Air in the gas circuit.
Open gas line and bleed it (pressing control
knob in) for not over 1 minute or until you
smell gas.
Low gas pressure.
Replace LPG cylinder with a new one.
Igniter fails.
Use match to light burner; change battery
or obtain new ignite and replace it
.
Burner won’t
stay lit
Dirty build up around burner.
Clean dirty around the burner.
Low flames or not full running
around the burner.
Flame spreader holes partially closed; clean
the burner.
Thermocouple is not operating
correctly.
Replace thermocouple (FSD).
Low Gas pressure.
Replace LPG cylinder with a new one.
Burner flame
is low
Note: Do
not operate
appliance
below 5 ˚C
Outdoor temperature is greater
than 5 ˚C and LPG cylinder is less
than 25 % full.
Replace LPG cylinder with a new one.
Gas pipe is bent or kinked.
Straighten hose and perform leakage test
on gas pipe.
Control knob is fully Maximum
position (big flame).
Turn control knob to”OFF” position (full disk),
let cool to room temperature and check
burner and orifices for blockage.
Carbon build-
up
Dirty or film on burner.
Clean burner.
Flash back
(flame inside
burner)
Burner ports are blocked.
Switch OFF the appliance. Close LPG
cylinder valve. Wait 2 minutes, following the
ignition procedure. Ignite burner. If problem
continuous, switch-off. Contact your dealer.
Thick black
smoke
Blockage in the burner.
Turn control knob to “OFF” position, let the
appliance to cool at room temperature and
remove blockage and clean burner inside
and outside.
Manual ATRIO.indd 27
30/4/21 13:29
Содержание ATRIO
Страница 54: ...Manual ATRIO indd 54 30 4 21 13 29...
Страница 56: ...Manual ATRIO indd 56 30 4 21 13 29...