User Manual
7
Warning:
The electric conductors are strictly prohibited to be connected with water supply pipes,
natural gas pipes and caliducts, otherwise, security accidents would be induced.
4.
An equal-potential connection screw is foreseen on the back area of the machine. In case that
any other equipment inside the same room have equal-potential connections, the
equal-potential connection screw of this machine should be connected to an equal-potential
terminal of the other equipment through a copper conductor with a section area of no less
than 2mm
2
.
Ⅳ
. Operation Procedure
1.
Before operation, pour water into the water tank until the surface of water reaches a height
of 10cm.
2.
Insert the three-pole power supply plug of the Awaken Fermenting Box into a proper socket,
and then turn on the circuit breaker in the power supply circuit, at this moment, the power
supply indicator lamp will light(red). Turn the temperature and humidity control knobs on the
control panel to desired position, and then, the temperature and humidity indicator lamps will
light(green), indicating that the Awaken Fermenting Box is in operation and is capable of
automatic operating within the setting range of temperature and humidity.
3.
When the machine is out of operation, the power supply should be switched off so as to
insure your safety.
4.
The machine is equipped with a water-lacking protection device. In case that the red power
supply indicator lamp is on and that the machine fails to operate even if the temperature and
humidity control knobs have been adjusted, please check for water level inside the water tank
and pour water into it until the water surface reaches a standard level, then, the machine will
be able to operate. In case that the machine still fails to operate, the power supply should be
switched off immediately and the machine needs to be inspected and repaired by professional
technicians.
Ⅴ
. Attention and Maintenance
1.
Regularly and often check the water level inside the water tank and insure that heating tubes
are dipped under the water surface so as to prevent the electro-thermal tubes from being
burned out. In case that these is no water inside the water tank, switching on the power
supply will be strictly prohibited so as to avoid any personal injury.
2.
The awaken fermentation temperature is between 35
℃
~
40
℃
, too high temperature will
influence the normal reproduction of the yeasts or even cause the death of them.
3.
The waterproof category of the machine is of ordinary grade (IPXO), and therefore it is
suitable for indoor operation only. The machine is strictly prohibited to be placed at a place
where spraying water may possibly occur. Cleaning the machine with water spraying from a
pipe or by dipping it into water will be strictly forbidden.
4.
The inside or outside area of the box body should be kept clean. The water in the water tank
should be replaced at least one time each day. The water tank should be kept in an condition
of cleanliness and sanitation. In case any dirt occurs on the surface of the machine, wipe and
clean it with a piece of cloth soaked in neutral cleanser solution. After the dirt has been
removed, wipe it with a piece of clean, wet cloth.
5.
The connection mode of the power supply circuit is of X type. In case of replacing the power
supply wires, rubber sheath wires with specification similar to that of the wire type
Yzw1.5mm
2
that has been equipped for this machine must be adopted.