ProDAQ 3150 User Manual
3150UM-01
Page 54
Bustec Production Ltd.
LOC_P2A_OUT
(0x0100 0002, read/write)
Bit
15 14 13 12
11
10
9
8
7
6
5
4
3
2
1
0
Operation R
R
R
R
RW
RW
RW RW RW RW RW RW RW RW RW RW
Initial
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Name
“0” “0” “0” “0”
P2A_
OUT11
P2A_
OUT 10
P2A_
OUT 9
P2A_
OUT 8
P2A_
OUT 7
P2A_
OUT 6
P2A_
OUT 5
P2A_
OUT 4
P2A_
OUT 3
P2A_
OUT 2
P2A_
OUT 1
P2A_
OUT 0
P2A_OUT 0 … 11
“1” : sets the VXI Local bus signals LBUSA0..11
if P2A-FET driver is enabled and ENABLE_P2A_ OUT_REG is
enabled
(ENABLE_LOC_P2A = 1 and ENABLE_P2A_ OUT_REG = 1)
LOC_P2C_OUT
(0x0100 0003, read/write)
Bit
15 14 13 12
11
10
9
8
7
6
5
4
3
2
1
0
Operation R
R
R
R
RW
RW
RW RW RW RW RW RW RW RW RW RW
Initial
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Name
“0” “0” “0” “0”
P2C_
OUT11
P2C_
OUT 10
P2C_
OUT 9
P2C_
OUT 8
P2C_
OUT 7
P2C_
OUT 6
P2C_
OUT 5
P2C_
OUT 4
P2C_
OUT 3
P2C_
OUT 2
P2C_
OUT 1
P2C_
OUT 0
P2C_OUT 0 … 11
“1” : sets the VXI Local bus signals LBUSC0..11
if P2C-FET driver is enabled and ENABLE_P2C_ OUT_REG is
enabled
(ENABLE_LOC_P2C = 1 and ENABLE_P2C_ OUT_REG = 1)
LOC_P2A_IN
(0x0100 0004, read)
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Operation
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Name
“0”
“0”
“0”
“0”
P2A_
IN11
P2A_
IN10
P2A_
IN9
P2A_
IN8
P2A_
IN7
P2A_
IN6
P2A_
IN5
P2A_
IN4
P2A_
IN3
P2A_
IN2
P2A_
IN1
P2A_
IN0
P2A_IN 0 … 11
Status of the VXI Local bus signals LBUSA0..11 (if P2A-FET driver is
enabled)
LOC_P2C_IN
(0x0100 0005, read)
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Operation
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Name
“0”
“0”
“0”
“0”
P2C_
IN11
P2C_
IN10
P2C_
IN9
P2C_
IN8
P2C_
IN7
P2C_
IN6
P2C_
IN5
P2C_
IN4
P2C_
IN3
P2C_
IN2
P2C_
IN1
P2C_
IN0
P2C_IN 0 … 11 Status of the VXI Local bus signals LBUSC0..11 (if P2C-FET driver is enabled)