OPERATING INSTRUCTIONS
The electrical control system integrated with the lifter must be equipped with an open and close
function. "Open" increases the gap between the lifting legs; "close" decreases the gap between the
lifting legs.
To operate the lifter, open the legs until the lifter is wider than the coil to be handled. Move the lifter
so that it is centered over the coil, and then lower it until the lifting shoes are centered on the coil ID.
Close the lifter until the legs engage both sides of the coil. Note: It may be necessary to re-center the
lifter over the coil to ensure proper engagement.
Slowly raise the coil grab until the coil begins to rise. Before continuing the lift, inspect the lifter and
coil to be sure the load is properly engaged. Make adjustments if necessary. Recheck the load path
and then proceed with the lift.
Transport the coil to its destination. Lower the lifter until the coil contacts the storage surface. Open
the coil lifter until the lifting shoes clear the coil. Raise the coil lifter above the coil and proceed to
next lift.
When lifting is complete, return the lifter to its properly designed storage stand. Prevent personal
injury by keeping hands and feet clear as the lifter is lowered into the stand.
When using lifter follow all safety instructions and warnings.