background image

Installation  

Customer Helpline 

0345 257 7271

Gas conversions

WARNING 

-

 

Gas conversions must only be carried 

out by suitably qualifi ed personnel.

The appliance can be converted to operate on LPG 
by replacing the appliance’s injectors and adjusting 
the minimum fl ame length.

Replacement injectors are supplied as part of the 
gas conversion kit.

Changing the hob burner injectors

IMPORTANT

 - The following procedure must be 

performed on each hob burner.

Disconnect the Gas supply and mains

1.

electricity supply from the appliance.

Remove the hob cap and adapter.

2.

Using a 7mm spanner, unscrew the injector

3.

as shown in fi gure 5.

Select an appropriate injector for the

4.

desired gas using the information chart
supplied with the gas conversion kit.

Fit the replacement injector to the appliance

5.

and tighten using a 7mm spanner.

Refi t the hob cap and adapter.

6.

Changing the grill injector

Open the oven door and locate the retaining

1.

screw on the tip of the grill burner as shown
in fi gure 6.

Remove the screw and withdraw the burner

2.

to reveal the injector as shown in fi gure 7.

Using a 7mm spanner, unscrew the injector.

3.

Select an appropriate injector for the

4.

desired gas using the information chart
supplied with the gas conversion kit.

Fit the replacement injector to the

5.

appliance.

Refi t the burner and screw.

6.

Figure 5

Figure 6

Figure 7

Spanner

Screw

Injector

7

Содержание AG56SB

Страница 1: ...ns fully before using These instructions contain important information that will help you get the best from your appliance ensuring safe and correct installation use and maintenance If you need help o...

Страница 2: ...y for the type of electrical supply in your house by checking the information on the rating plate WARNING The appliance must be installed by an authorised technician prior to use The manufacturer is n...

Страница 3: ...ctly in which case no permanent ventilation is required For rooms with a volume greater than 10 m no permanent ventilation is required Pay attention Regardless of room size all rooms containing the ap...

Страница 4: ...the back wall and the rear of the appliance to allow ventilation and air circulation If fitted the extractor fan must be at least 5 65cm above the hob If no extractor fan is fitted the minimum distan...

Страница 5: ...tions You can find the information related to appropriate gas types and appropriate gas injectors in the Technical Specifications of the Operating Instructions If the gas pressure used is different to...

Страница 6: ...located adjacent to the appliance within a maximum distance of 2m The switched FCU must not be located above the appliance but should be easily accessible in case of an emergency Electrical connectio...

Страница 7: ...ew the injector 3 as shown in figure 5 Select an appropriate injector for the 4 desired gas using the information chart supplied with the gas conversion kit Fit the replacement injector to the applian...

Страница 8: ...ve the screw and withdraw the burner 3 diagonally to reveal the injector as shown in figure 9 Using a 7mm spanner unscrew the injector 4 Select an appropriate injector for the 5 desired gas using the...

Отзывы: