background image

Fixed gas connection

The appliance is supplied with the most common 
parts required to connect the appliance to a fi xed 
gas connected.

Additional spares can be supplied by calling 
the Customer Helpline on 

0345 257 7271

.

If the appliance is to be connected to the gas inlet 
using a fi xed gas connection, the following 

must

 

be observed:

The nut on the gas manifold 

must

 always

remain in a fi xed position. Only rotate mating
parts.

Use the correct size tools for all connections.

Only the supplied seals should be used. 

Do

not

 use plumbing seals to make connections.

Alternative supplies

The appliance is equipped for connection in the 
country of manufacture. This is indicated on the 
rating plate of the appliance.

If the appliance is to be used in another country, 
the alternative connections shown in fi gure 3 
may be used. 

You must 

only use the alternative 

connections designed for the selected supply.

The connection of the appliance should be 
performed in accordance with local and 
international standards and applicable regulations.

You can fi nd the information related to appropriate 
gas types and appropriate gas injectors in 
the Technical Specifi cations of the Operating 
Instructions.

If the gas pressure used is different to the values 
in the Technical Specifi cations or the gas supply 
pressure is not stable, the gas inlet requires a 
pressure regulator.

You must contact your authorised service agent to 
make these changes.

Flexible hose connection

If the appliance is to be connected to the gas 
inlet with a fl exible hose, the following 

must

 be 

observed:

The fl exible hose must be secured with a pipe
collar.

The fl exible hose must not exceed 1.5m in
length and should be kept as short as possible.

Inspect the fl exible hose prior to installation and
annually for signs of damage including ruptures,
bends or folds. 

Do not

 use damaged hoses.

Make sure the fl exible hose is located away
from sharp objects.

WARNING

 – Do not use naked fl ames or sources 

of ignition to perform leak tests.

All connections including the fl exible hose must
be leak tested using a suitable fl uid.

IMPORTANT

 – Make sure all metal connections 

are free from rust. Rust may pose a potential 
source of ignition.

Installation

  

Customer Helpline 

0345 257 7271

Gas connection

Figure 3

5

Содержание AG56SB

Страница 1: ...ns fully before using These instructions contain important information that will help you get the best from your appliance ensuring safe and correct installation use and maintenance If you need help o...

Страница 2: ...y for the type of electrical supply in your house by checking the information on the rating plate WARNING The appliance must be installed by an authorised technician prior to use The manufacturer is n...

Страница 3: ...ctly in which case no permanent ventilation is required For rooms with a volume greater than 10 m no permanent ventilation is required Pay attention Regardless of room size all rooms containing the ap...

Страница 4: ...the back wall and the rear of the appliance to allow ventilation and air circulation If fitted the extractor fan must be at least 5 65cm above the hob If no extractor fan is fitted the minimum distan...

Страница 5: ...tions You can find the information related to appropriate gas types and appropriate gas injectors in the Technical Specifications of the Operating Instructions If the gas pressure used is different to...

Страница 6: ...located adjacent to the appliance within a maximum distance of 2m The switched FCU must not be located above the appliance but should be easily accessible in case of an emergency Electrical connectio...

Страница 7: ...ew the injector 3 as shown in figure 5 Select an appropriate injector for the 4 desired gas using the information chart supplied with the gas conversion kit Fit the replacement injector to the applian...

Страница 8: ...ve the screw and withdraw the burner 3 diagonally to reveal the injector as shown in figure 9 Using a 7mm spanner unscrew the injector 4 Select an appropriate injector for the 5 desired gas using the...