background image

 18 

 

TROUBLE SHOOTING

 

 
Engine will not start: 
 

Does the output  

indicator light  

illuminate? 

YES 

Check fuel 

NO 

Does the overload 

indicator light  

illuminate? 

YES 

Disconnect all 

appliances 

NO 

Does the low oil  

indicator light  

illuminate? 

YES 

Fill with oil 

NO 

Contact Bushpower 

Содержание G2000i

Страница 1: ...1 G2000i INVERTER GENERATOR ...

Страница 2: ...s operation and safety devices Please take time to read this manual Please pay careful attention to any direction or comment with the following labels Operating the generator contrary to instruction manual may cause injury or death Ensure you operate the generator as per instruction manual failure to do so could damage the generator and void the warranty ...

Страница 3: ...e Number Safety 4 Parts Identification 5 Before starting 7 Starting the generator 10 Operation 11 Alarms 13 Shutting down 13 Maintenance 14 Transport Storage 16 Trouble shooting 17 Specifications 19 Warranty Statement 20 ...

Страница 4: ...erating the generator ensure there is adequate ventilation Failure to do so could result in injury or death When filling the generator with petrol ensure the area is well ventilated Ensure no sparks or flames are near the generator If petrol is spilt or overflows from generator DO NOT start the generator until ALL excess fuel has been washed away Ensure petrol filler cap is on tight and vent is in...

Страница 5: ...5 PARTS INDENTIFICATION Control Panel Filler cap and vent switch Engine start and run switch Maintenance cover Starting pull handle Engine ON OFF switch Engine exhaust Spark plug cover ...

Страница 6: ...6 PARTS INDENTIFICATION 240Volt AC outlets Low oil indicator Overload indicator Output indicator Economy switch DC outlet and reset switch LCD Display Output Volts Output Hertz KW output Total Hours ...

Страница 7: ...supplied fill generator with 400ml When checking oil level remove dip stick wipe with a clean cloth and place dip stick back in Remove and read dip stick Ad oil as needed Ensure generator is on a flat surface and a minimum of one meter from any building or obstruction Oil must be added to the generator before first operation Failure to do so will damage the generator and void warranty Oil dip stic...

Страница 8: ...f petrol ensure all petrol is washed away before starting the generator Replace filler cap and turn on vent for operation Always use ULP petrol use of leaded or E10 petrol will damage the generator and void warranty When filling the generator with fuel ensure the area is well ventilated and free from flames or sparks and generator not running Fuel Filler cap ...

Страница 9: ...ntenance panel from generator 3 Remove retaining screw from air filter cover 4 Remove air filter cover 5 Check core of air filter for excessive dirt and particles 6 If core is dirty clean as per instructions detailed later in the manual 7 Replace air filter cover and screw into place 8 Replace maintenance cover and screw into place Do not run the generator without the air filter in place Failure t...

Страница 10: ...urn vent valve on fuel filler cap to on position 2 Turn the engine switch to the on position 3 Turn engine run start switch to start 4 Pull starting handle firmly to start motor release handle gently back into position Once engine is running approximately one minute turn engine run start switch back to run On and Off indicator Engine on off switch ...

Страница 11: ... cables and connections are suitably protected from becoming wet In order to prevent electric shock the engine should be suitably earthed from the earth port on the control panel Earth point Do not exceed rated power of generator Do not exceed amperage of 240Volt AC outlet The generator is not to be connected to mains power Do not make modifications to the motor Maximum cable length from genera to...

Страница 12: ...nect charging clamps 5 Turn generator off Reverse connection when removing charge DC output is to be used for charging sealed lead acid batteries only The DC output is not designed to be used as a DC power source Charging cable Batteries release explosive gasses during charge Always charge batteries in a well ventilated area Keep flame and sparks away from charging batteries Check battery manufact...

Страница 13: ...d at 2000 watts with a constant output of 1700 watts If the appliance connected is drawing a higher wattage than the above rating the generator overload warning light will illuminate Continued use of the generator above the recommended limit will result in the generator shutting down automatically DC reset switch If the rated amperage is exceeded the generator will cut power to the DC outlet If th...

Страница 14: ...l with recommended oil 400ml 5 Replace oil dip stick 6 Replace maintenance cover Ensure the generator is OFF and cool before carrying out any maintenance Item period Each use 1 month or 20 hours 3 months or 50 hours 6 months or 100 hours 12 months or 200 hours Oil check change Air filter check change Spark Plug clean change Fuel filter clean ...

Страница 15: ...ulation 5 If this has occurred you will need to replace the spark plug 6 Clean the spark plug with a wire brush removing all deposits 7 Measure the clearance of the spark plug with a gauge adjust as needed 8 Re install the spark plug by hand taking care not to cross thread 9 Carefully tighten the spark plug with the supplied spanner 10 Firmly push spark plug cap back onto spark plug 11 Replace spa...

Страница 16: ...ect sunlight for long periods of time if transporting in the cabin of the vehicle Direct sunlight will cause the petrol to expand and produce excessive fumes Long Term Storage 1 Empty fuel tank of the generator by syphoning fuel into an appropriate container 2 Replace petrol cap and ensure vent is set to the off position 3 Remove side panel of generator 4 Remove oil dip stick 5 Tilt the generator ...

Страница 17: ... not start Fuel in tank NO Fill with fuel YES Is the engine start switch in the ON position NO Switch ON YES Is there enough oil in the generator Fill oil NO YES Check spark plug for spark NO Replace spark plug YES Contact Bushpower ...

Страница 18: ... not start Does the output indicator light illuminate YES Check fuel NO Does the overload indicator light illuminate YES Disconnect all appliances NO Does the low oil indicator light illuminate YES Fill with oil NO Contact Bushpower ...

Страница 19: ...verhead air valve one cylinder Compression 8 8 1 RPM 4300 Cooling Direct induction Ignition Transistor Oil Capacity 0 4L Fuel Capacity 3 7L Spark Plug A7RC Displacement 113cc Frequency 50Hz Volts 240V AC Amperage 7 4 Continuous Output 1700W Peak Output 2000W DC Output 12V 6Amp Noise level zero load full load 59 64db 7m ...

Страница 20: ... Warranty Card Name Company Name Address Ph Fax E mail Purchased From Date Purchased Product Purchased Model No Return Authority Number Please Note Proof of purchase will be required for all warranty claims Refer to the full warranty statement at www bushpower com au This product is covered by a 12 month warranty ...

Отзывы: