![BUSCH RA 0400 C Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/busch/ra-0400-c/ra-0400-c_instruction-manual_2833642027.webp)
Decommissioning | 9
0870201532_RA_RC0400-0630C_-0003_O2_IM_en
27 / 32
9
Decommissioning
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
Version with water-oil heat exchanger:
• Turn off the water supply.
• Disconnect the water supply.
• Open the water bypass valve (WBV).
• Blow through the water cooling inlet with compressed air.
• Disconnect all connections.
If the machine is going to be stored:
• See
9.1 Dismantling and Disposal
• Drain the oil.
• Remove the exhaust filters.
• Remove the oil filter.
• Separate special waste from the machine.
• Dispose of special waste in compliance with applicable regulations.
• Dispose of the machine as scrap metal.
10 Spare Parts
NOTICE
Use of non-Busch genuine spare parts.
Risk of premature failure!
Loss of efficiency!
• The exclusive use of Busch genuine spare parts and consumables is recommended for
the correct functioning of the machine and to validate the warranty.
WARNING
Use of non-Busch genuine spare parts.
Risk of fire!
• Only use Busch spare parts approved by Busch and suitable for oxygen application.
Spare parts kit
Description
Part no.
Service kit
(RA 0400 / 0502 / 0630 C
“O2”)
Includes all the necessary parts for main-
tenance.
0992 537 267
If other parts are required:
• Contact your Busch representative for the detailed spare parts list.