![BUSCH RA 0400 C Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/busch/ra-0400-c/ra-0400-c_instruction-manual_2833642014.webp)
5 | Installation
14 / 32
0870201532_RA_RC0400-0630C_-0003_O2_IM_en
5.4 Fitting the Coupling
E
L
Coupling hub (machine side)
Coupling hub (motor side)
Coupling sleeve
Radial screw
Max. admissible
torque: 17 Nm
In case of a machine delivery without motor:
• Fit the second coupling hub on the motor shaft (separately delivered).
• Axially adjust the sleeve in such a way until value "E" (or “L”) is reached.
• When the coupling adjustment is done, lock the coupling hub by tightening the
radial screw.
• Mount the motor on the machine by including the coupling sleeve.
For further coupling information, go to
manual of the BoWex
®
coupling.
5.5 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
NOTE
The operation with variable speed, i.e. with a variable-frequency drive or a soft starter
unit, is allowed as long as the motor is admitted and the permitted motor speed range is
neither underrun nor exceeded (see
Seek advice from your Busch representative.
• Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
• The electrical installation must comply with applicable national and international
standards.
• Provide a lockable disconnect switch on the power line so that the machine is com-
pletely secured during maintenance tasks.
• Provide an overload protection according to EN 60204-1 for the motor.