![BUSCH RA 0400 C Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/busch/ra-0400-c/ra-0400-c_instruction-manual_2833642015.webp)
Installation | 5
0870201532_RA_RC0400-0630C_-0003_O2_IM_en
15 / 32
• Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
• Connect the protective earth conductor.
• Electrically connect the motor.
NOTICE
Incorrect connection.
Risk of damage to the motor!
• The wiring diagrams given below are typical. Check the inside of the terminal box for
motor connection instructions/diagrams.
5.5.1 Wiring Diagram Three-Phase Motor
NOTICE
Incorrect direction of rotation.
Risk of damage to the machine!
• Operation in the wrong direction of rotation can destroy the machine in a short time!
Prior to start-up, ensure that the machine is operated in the right direction.
• Determine the intended direction of rotation with the arrow (stuck on or cast).
• Jog the motor briefly.
• Watch the fan wheel of the motor and determine the direction of rotation just before
the fan wheel stops.
If the rotation of the motor must be changed:
• Switch any two of the motor phase wires.
Delta connection (low voltage):
Star connection (high voltage):
Double star connection, multi-voltage
motor with 12 pins (low voltage):
4
4
4
Star connection, multi-voltage motor
with 12 pins (high voltage):
4
4
4