Installation | 5
0870573103_RA0160-0302D_O2_-0001_IM_en
9 / 28
5
Installation
WARNING
Lack of oxygen regulation knowledge.
Risk of fire!
• Installation, commissioning and maintenance must only be carried out by qualified
personnel who are informed about the applicable safety regulations and trained in the
handling of oxygen.
• Accident prevention regulations or methods must imperatively be complied with.
Seek further information:
- European Industrial Gases Association “EIGA” www.eiga.eu (EIGA SAG NL 79/04).
- Berufsgenossenschaft Rohstoffe und chemische Industrie "BG RCI”
www.bgrci.de
(Merkblatt M 034 Sauerstoff).
5.1 Installation Conditions
WARNING
The machine is not absolutely gas tight.
Risk of fire!
• The installation area must be aired in such a way so as to prevent unacceptable levels
of oxygen.
~20 cm
~50 cm
~20 cm
~50 cm
• Make sure that the environment of the machine is not potentially explosive.
• Make sure that the ambient conditions comply with the
Technical Data [
}
26]
.
• Make sure that the environmental conditions comply with the protection class of the
motor.
• Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
• Make sure that cooling air inlets and outlets are not covered or obstructed and that
the cooling air flow is not affected adversely in any other way.
• Make sure that the oil sight glass (OSG) remains easily visible.