Maintenance | 7
0870573103_RA0160-0302D_O2_-0001_IM_en
17 / 28
START
Open the gas ballast
valve* (GB)
Warm up the
machine
30 minutes
30 minutes
• Open the inlet valve
• Perform the process
• Close the inlet valve
Close the gas ballast
valve*
END
* may be considered as optional on certain products
7
Maintenance
WARNING
Lack of oxygen regulation knowledge.
Risk of fire!
• Installation, commissioning and maintenance must only be carried out by qualified
personnel who are informed about the applicable safety regulations and trained in the
handling of oxygen.
• Accident prevention regulations or methods must imperatively be complied with.
Seek further information:
- European Industrial Gases Association “EIGA” www.eiga.eu (EIGA SAG NL 79/04).
- Berufsgenossenschaft Rohstoffe und chemische Industrie "BG RCI”
www.bgrci.de
(Merkblatt M 034 Sauerstoff).
WARNING
Machine contaminated with organic material.
Risk of fire!
If there is a suspicion that the machine or the oil is contaminated with organic material:
• The machine must be removed from service and cleaned by specialists (contact your
Busch representative).
WARNING
Use of non-Busch genuine spare parts.
Risk of fire!
• Only use Busch spare parts approved by Busch and suitable for oxygen application.