Decommissioning | 9
0870203785_WZ3600A_-0001_IM_en
23 / 28
9
Decommissioning
• Shut down the machine and lock against inadvertent start up.
• Turn off the water supply.
• Vent the connected lines to atmospheric pressure.
• Blow through the water cooling inlet with compressed air.
• Disconnect all connections.
If the machine is going to be stored:
• See
9.1 Dismantling and Disposal
• Drain the oil.
• Separate special waste from the machine.
• Dispose of special waste in compliance with applicable regulations.
• Dispose of the machine as scrap metal.
10 Spare Parts
NOTICE
Use of non-Busch genuine spare parts.
Risk of premature failure!
Loss of efficiency!
• The exclusive use of Busch genuine spare parts and consumables is recommended for
the correct functioning of the machine and to validate the warranty.
There is no standard spare parts kits available for this product, if you require Busch gen-
uine parts:
• Contact your Busch representative for the detailed spare parts list.
11 Troubleshooting
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.