5 | Installation
14 / 32
0870231039_LG_LR_-_IM_en
LR 0700 A
Speed
r/min
< 200 mbar
m³/h
200 - 400 mbar
m³/h
400 - 600 mbar
m³/h
> 600 mbar
m³/h
490
472
420
372
330
19.0 - 20.0
17.5 - 18.5
15.5 - 16.5
13.5 - 14.5
12.0 - 13.0
15.5 - 16.5
14.0 - 15.0
12.5 - 13.5
11.0 - 12.0
9.5 - 10.5
13.0 - 14.0
11.5 - 12.5
10.0 - 11.0
9.0 - 10.0
8.0 - 9.0
6.5 - 7.5
5.5 - 6.5
5.0 - 6.0
4.5 - 5.5
4.0 - 5.0
LR 1190 A
Speed
r/min
< 200 mbar
m³/h
200 - 400 mbar
m³/h
400 - 600 mbar
m³/h
> 600 mbar
m³/h
472
420
372
330
298
266
22.1 - 22.6
19.6 - 20.1
17.1 - 17.8
15.4 - 15.8
13.8 - 14.2
12.4 - 12.8
19.2 - 22.1
17.1 - 19.6
15.2 - 17.1
13.4 - 15.4
12.1 - 13.8
10.9 - 12.4
14.1 - 19.2
12.5 - 17.1
11.1 - 15.2
9.9 - 13.4
8.9 - 12.1
7.9 - 10.9
9.0 - 14.1
7.9 - 12.5
7.1 - 11.7
5.9 - 9.9
5.7 - 8.9
5.1 - 7.9
LR 1560 A
Speed
r/min
< 200 mbar
m³/h
200 - 400 mbar
m³/h
400 - 600 mbar
m³/h
> 600 mbar
m³/h
398
372
330
298
266
236
30.8 - 31.7
28.7 - 29.6
25.4 - 26.3
22.9 - 23.7
20.4 - 21.2
17.9 - 18.7
26.6 - 30.8
24.9 - 28.7
22.0 - 25.4
19.9 - 22.5
17.7 - 21.2
15.8 - 17.9
19.4 - 26.6
18.1 - 24.9
16.0 - 22.0
14.0 - 19.9
13.0 - 17.7
11.5 - 15.8
12.5 - 19.4
11.7 - 18.1
10.3 - 16.0
9.4 - 17.5
8.3 - 13.0
7.4 - 11.5
LR 2200 A
Speed
r/min
< 200 mbar
m³/h
200 - 400 mbar
m³/h
400 - 600 mbar
m³/h
> 600 mbar
m³/h
330
298
266
236
210
41.2 - 42.8
37.1 - 37.9
33.0 - 35.4
29.7 - 31.3
26.4 - 28.0
36.4 - 42.7
37.1 - 38.5
29.3 - 34.0
26.0 - 30.6
23.2 - 27.2
26.6 - 36.4
24.1 - 32.9
21.5 - 29.3
19.1 - 26.0
17.0 - 23.2
17.1 - 26.6
15.4 - 24.1
13.7 - 21.5
12.2 - 19.1
10.9 - 17.0
Water pressure before flow regulation valve
(once through operation only)
bar(g)
1
Max. allowable supply temperature
°C
80
Max. allowable kinematic viscosity
mm
2
/s
20
Consider the motor power for
anything other than water -
consult Busch.
Max. allowable particle size
mm
0.4*