background image

Table of Contents

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Product description . . . . . . . . . . . . . . . . . . . . . . . . . 3

NC 400 B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operating principle . . . . . . . . . . . . . . . . . . . . . . . . 3

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety information . . . . . . . . . . . . . . . . . . . . . . . . 3
Use in explosive atmosphere

. . . . . . . . . . . . . . . . 4

Use of the magnetic coupling on ATEX category 3 Gi/o

certified pump . . . . . . . . . . . . . . . . . . . . . . . . . 4
Use of the magnetic coupling on ATEX category 2 Gi/o

certified pump . . . . . . . . . . . . . . . . . . . . . . . . . 4

Installation and commissioning. . . . . . . . . . . . . . . . . . . 4

Installation Prerequisites . . . . . . . . . . . . . . . . . . . . . 4

Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Maintenance Precautions . . . . . . . . . . . . . . . . . . . . . 5
Fitting the magnetic coupling. . . . . . . . . . . . . . . . . . . 5

Step 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Step 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Step 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Step 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Dismantling the motor/ the lanterne/ the exterior coupling . . . . 6
Fitting the motor/ the lanterne/ the exterior coupling . . . . . . . 7

Inactivity of the vacuum pump for longer periods of time . . . . 7

EC-Declaration of Conformity . . . . . . . . . . . . . . . . . . . 9

Introduction

COBRA Vacuum Pump with Magnetic Coupling

Page 2

0870549497 (EN)

This complement contains further instructions concerning the installa-
tion and operation of the COBRA vacuum pump equipped with ma-
gnetic coupling.

Introduction

Congratulations on the purchase of your Busch vacuum pump. Whilst
always responding to customers’ requirements and through constant
innovation and improvements, Busch delivers modern vacuum and
pressure solutions at the head of Industry worldwide.

This complement to the Roots Installation and Operating Instructions
contains information on

product description

safety

installation

maintenance

overhaul

dismantling

of the vacuum pump with magnetic coupling.

In these instructions, the “handling ” of the vacuum pump implies the
transport, storage, installation, commissioning, influences on operating
conditions, maintenance, troubleshooting and overhaul of the vacuum
pump.

Prior to handling the vacuum pump, these operating instructions must
be read and understood. If you have any doubts, please contact your
Busch representative.

Keep these operating instructions and, if applicable, other relevant ope-
rating instructions available and accessible on site.

Содержание COBRA NC 400 B

Страница 1: ...ion and Maintenance manual COBRA Vacuum Pump with Magnetic Coupling Screw Vacuum Pumps COBRA NC 400 B Ateliers Busch S A Zone industrielle 2906 Chevenez Switzerland 0870549497 081209 Original instruct...

Страница 2: ...la tion and operation of the COBRA vacuum pump equipped with ma gnetic coupling Introduction Congratulations on the purchase of your Busch vacuum pump Whilst always responding to customers requirement...

Страница 3: ...the pump as well as influences on operating conditions maintenance troubleshooting and overhaul of the vacuum pump The vacuum pump is intended for industrial use It may only be opera ted by qualified...

Страница 4: ...rtified category 2G i o pumps the temperature class must be watched by measuring the surface temperature of the cera mic bell using a PT100 temperature sensor installed on the pump WARNING Minimum obl...

Страница 5: ...tem is carried out or where parts of the magne tic coupling system are stored with the danger sign No trespassing for persons with pacemaker Do not place the dismantled magnetic coupling into the vici...

Страница 6: ...ure to keep good control over the axial forces Risk of squashed fingers Tighten the screws 432 Dismantling the motor the lanterne the exterior coupling CAUTION Always make sure that the vacuum pump is...

Страница 7: ...s with the help of the two guiding rods These help to com pensate radial forces CAUTION While mounting this unit control the axial force Risk of squashing fingers due to the effect of magnetism Inacti...

Страница 8: ...Note...

Страница 9: ...e within Certain Voltage Limits so called Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC have been designed and manufactured to the following specifications Standard Title of the Sta...

Страница 10: ...Note...

Страница 11: ...Note...

Страница 12: ...ss Centre Kilbarrack Dublin 5 Tel 00353 1 832 1466 Fax 00353 1 832 1470 Israel Busch Israel Ltd 1 Mevo Sivan Street Qiryat Gat 82022 Israel Tel 972 0 8 6810485 Fax 972 0 8 6810486 Italy Busch Italia S...

Отзывы: