CAUTION

Please handle the ceramic bell housing carefully to prevent dama-
ging it.

Tighten up and glue the fixing screws (12) to a maximum torque
of 6 Nm.

Step 3

Fit the coupling (13) onto the motor shaft (480).

Note: The coupling (13) can come in 2 parts: the exterior rotor of the
coupling and flange hub. Those parts are fitted and glued using 4 M6
screws, then tightened to a torque of 10Nm.

Measure and adjust the distance between the coupling face (13)
and the motor flange (480). This value must be 217 mm. Lock
with the fixing screw (14).

Fit the protection grid (431) into the motor lantern.

Mount the motor lantern (430) onto the motor (480). Tighten with
the screw (436).

Step 4

Carefully fit the motor/ lantern/ exterior rotor unit onto the pump.
The two guiding rods will compensate the radial forces coming
from the magnets. Make sure to keep good control over the axial
forces ! (Risk of squashed fingers!)

Tighten the screws (432).

Dismantling the motor/ the
lanterne/ the exterior coupling

CAUTION

Always make sure that the vacuum pump is disconnected from the
power supply when carrying out any work on the pump.

If necessary, remove the vacuum pump from the system to carry out
any work.

DANGER

Danger of personal injury whilst dismantling/assembling the com-
ponents.

When dismantling the Roots pump (replacing internal components),
separate the motor/ lantern unit from the pump body.

The motor, the lantern and the exterior coupling must not be separa-
ted during dismantling.

To do this, follow the following instructions:

Unscrew the bolts pins from the motor/lantern unit

Remove the motor/lantern unit with the help of the guiding
rods.The access to the internal components is now given.

Dismantling the motor/ the lanterne/ the exterior coupling

COBRA Vacuum Pump with Magnetic Coupling

Page 6

0870549497 (EN)

7 / 8

11

10

12

9

15

480

14

13

430

431

436

432

Содержание COBRA NC 400 B

Страница 1: ...ion and Maintenance manual COBRA Vacuum Pump with Magnetic Coupling Screw Vacuum Pumps COBRA NC 400 B Ateliers Busch S A Zone industrielle 2906 Chevenez Switzerland 0870549497 081209 Original instruct...

Страница 2: ...la tion and operation of the COBRA vacuum pump equipped with ma gnetic coupling Introduction Congratulations on the purchase of your Busch vacuum pump Whilst always responding to customers requirement...

Страница 3: ...the pump as well as influences on operating conditions maintenance troubleshooting and overhaul of the vacuum pump The vacuum pump is intended for industrial use It may only be opera ted by qualified...

Страница 4: ...rtified category 2G i o pumps the temperature class must be watched by measuring the surface temperature of the cera mic bell using a PT100 temperature sensor installed on the pump WARNING Minimum obl...

Страница 5: ...tem is carried out or where parts of the magne tic coupling system are stored with the danger sign No trespassing for persons with pacemaker Do not place the dismantled magnetic coupling into the vici...

Страница 6: ...ure to keep good control over the axial forces Risk of squashed fingers Tighten the screws 432 Dismantling the motor the lanterne the exterior coupling CAUTION Always make sure that the vacuum pump is...

Страница 7: ...s with the help of the two guiding rods These help to com pensate radial forces CAUTION While mounting this unit control the axial force Risk of squashing fingers due to the effect of magnetism Inacti...

Страница 8: ...Note...

Страница 9: ...e within Certain Voltage Limits so called Low Voltage 2006 95 EC Electromagnetic Compatibility 2004 108 EC have been designed and manufactured to the following specifications Standard Title of the Sta...

Страница 10: ...Note...

Страница 11: ...Note...

Страница 12: ...ss Centre Kilbarrack Dublin 5 Tel 00353 1 832 1466 Fax 00353 1 832 1470 Israel Busch Israel Ltd 1 Mevo Sivan Street Qiryat Gat 82022 Israel Tel 972 0 8 6810485 Fax 972 0 8 6810486 Italy Busch Italia S...

Отзывы: