Maintenance | 7
Instruction Manual COBRA NC 1000 B WCV_EN_en
19 / 32
6.1 Conveying Condensable Vapours
The machine, equipped either with a gas ballast valve or a dilution gas system, is suit-
able for the conveyance of condensable vapours within the gas flow.
If condensable vapours are to be conveyed:
START
Open the gas ballast
valve* or the
dilution gas sytem*
(solenoid valve)
Warm up the
machine
30 minutes
30 minutes
• Open the inlet
valve
• Perform the
process
• Close the inlet
valve
Close the gas ballast
valve*
or
the dilution gas
system*
END
* optional
accessories
• Continuously drain condensate from the condensate drain plug (CD) of the silencer
(SI) (Optional).
7
Maintenance
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
NOTICE
Using inappropriate cleaners.
Risk of removing safety stickers and protective paint!
• Do not use incompatible solvents to clean the machine.
CAUTION
Failing to properly maintain the machine.
Risk of injuries!
Risk of premature failure and loss of efficiency!
• Respect the maintenance intervals or ask your Busch representative for service.
Содержание COBRA NC 1000 B
Страница 31: ...Note...