Maintenance | 7
0870567092_NC0630C_WCV_A0006_IM_en
25 / 40
6.3 Gas Purging Procedure
The machine can optionally be equipped with a purge gas system.
If after the application process a gas purge is required, i.e. after a liquid flushing se-
quence or to render the compression chamber inert:
START
Close the inlet valve
Open the purge gas
(solenoid valve)
The flushing duration
depends on the application
Close the purge gas
END
min. 200 seconds to render
the machine inert
7
Maintenance
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
NOTICE
Using inappropriate cleaners.
Risk of removing safety stickers and protective paint!
• Do not use incompatible solvents to clean the machine.
CAUTION
Failing to properly maintain the machine.
Risk of injuries!
Risk of premature failure and loss of efficiency!
• Respect the maintenance intervals or ask your Busch representative for service.
• Shut down the machine and lock against inadvertent start up.
• Turn off the water supply.
If the machine is equipped with a barrier gas system:
Содержание COBRA NC 0600 C
Страница 38: ...Note...
Страница 39: ...Note...